Page 3
LZOD*1C, LZO8*1C, LZO8*2CJO, LZO8*3CJO HANGER BRACKETS & TRAP INSTALLATION 1) Remove hanger bracket fastened to back of cooler by removing one (1) screw. 2 ) Mount the hanger bracket as shown in Figure 2. NOTE: Hanger Bracket MUST be supported securely. Add fixture support carrier if wall will not provide adequate support. Anchor hanger securely to wall using all six (6) 1/4 in.
LZOD*1C, LZO8*1C, LZO8*2CJO, LZO8*3CJO Service Instructions Lower and Upper Shroud Bubbler To access the refrigeration system and plumbing connections, remove four screws from bottom of cooler to remove the lower shroud. To remove the upper shroud for access to the pushbars, regulator, solenoid valve or other components located in the top of the unit, remove lower shroud, disconnect drain, remove four screws from tabs along lower edge of upper shroud, unplug two wires and water tube.
Page 5
LZOD*1C, LZO8*1C, LZO8*2CJO, LZO8*3CJO WIRING DIAGRAM - LZO 230V BLACK LED PCB WHITE GREEN 230V PARTS LIST YELLOW PURPLE SENSOR ITEM NO. PART NO. DESCRIPTION OVERLOAD SOLENOID VALVE GREEN 36066C Power Cord 31431C Fan Motor COMPRESSOR COLD 33133000 Adapt - Tab .250 CONTROL 36248C Valve - Solenoid...
Page 6
PARA PIEZAS, CONTACTE A SU DISTRIBUIDOR LOCAL O LLAME AL 1.800.323.0620 IMPRIMÉ AUX É.-U. POUR OBTENIR DES PIÈCES, CONTACTEZ VOTRE DISTRIBUTEUR LOCAL OU COMPOSEZ LE 1.800.323.0620 ELKAY MANUFACTURING COMPANY • 2222 CAMDEN COURT • OAK BROOK, IL 60523 • 630.574.8484 98398C (Rev. D - 9/09) Page 6...