Install Range Hood In-Line (External Type) Blower Motor - KitchenAid KVWC956JSS0 Installation Instructions And Use & Care Manual

36" (91.4 cm) and 48" (121.9 cm) designer commercial-stylewall-mount canopy range hood
Table of Contents

Advertisement

4. Push the right end of the motor mounting plate up and snap it
into the spring tab.
NOTE: The spring tab should be outside the slot in the
mounting plate.
A. Motor mounting plate
B. Spring clip
5. Align mounting holes and install 6 x 16 mm screws and
6.4 mm lock washers.
A
B
A. Screw with lock washer
B. Mounting hole
6. Attach power supply connector from the range hood to the
connector on the blower motor assembly wiring box.
A
B
A. Wiring box connector
B. Power supply connector from range hood
7. Go to the "Make Electric Power Supply Connection to Range
Hood" section.
10
Install Range Hood In-Line (External Type)
NOTE: Your range hood requires you to purchase either an
internal type or an in-line (external type) blower motor system.
See "Blower Motor System" in the "Accessories" section.
Prepare for Mounting the In-Line Blower System
A
The in-line blower system must be fastened to a secure structure
of the roof, ceiling, wall, floor, or new or existing frame
construction. The 4 holes on either the inlet (bottom) side or the
outlet (top) side of the blower must be used to mount the in-line
blower system to the structure.
NOTE: The mounting hole locations must span the studs.
Additional stud framing may be required. Plywood may be used
B
to span open areas between ceiling joists or roof rafters to aid
installation. This structure must be strong enough to support the
weight of the in-line blower system (50 lb [22.6 kg] min).
Prepare the In-line Blower System
Use two or more people to move and install in-line
blower motor system.
Failure to do so can result in back or other injury.
1. Using 2 or more people, move the in-line blower motor
system to the mounting location.
2. Remove the 10 screws from the front cover of the in-line
blower motor housing and set them aside.
3. Remove the front cover of the in-line blower motor housing
and set it aside.
NOTE: To make the blower motor housing easier to mount,
the blower motor assembly can be removed. If you do not
want to remove the blower motor assembly, proceed to
"Install In-line Blower System" in this section.
4. Disconnect the motor electrical plug from the blower motor
assembly.
5. Remove the screws that secure the blower motor assembly
to the in-line blower housing and set them aside.
6. Pull the spring clip to release the blower motor assembly.
Remove the blower motor assembly from the housing and
place it on a covered surface.
Blower Motor
WARNING
Excessive Weight Hazard
A
D
A. Front cover
B. Blower mounting screws
C. Spring clip
D. Motor electrical plug
B C