M3057-PLR Mk II Dome Camera
Specifications
Function
DC ground
DC output
Digital Input or
Supervised Input
Digital Output
Function
DC ground
DC output
Configurable
(Input or Output)
Function
DC ground
DC output
Configurable
(Input or Output)
Example
Pin
Notes
1
2
Can be used to power auxiliary equipment.
Note: This pin can only be used as power out.
3
Connect to pin 1 to activate, or leave floating (unconnected)
to deactivate. To use supervised input, install end-of-line
resistors. See connection diagram for information about how
to connect the resistors.
4
Internally connected to pin 1 (DC ground) when active,
and floating (unconnected) when inactive. If used with an
inductive load, e.g., a relay, connect a diode in parallel with
the load, to protect against voltage transients.
Pin
Notes
1
2
Can be used to power auxiliary equipment.
Note: This pin can only be used as power out.
3–4
Digital input or Supervised input – Connect to pin 1 to activate, or
leave floating (unconnected) to deactivate. To use supervised input,
install end-of-line resistors. See connection diagram for information
about how to connect the resistors.
Digital output – Internally connected to pin 1 (DC ground) when
active, and floating (unconnected) when inactive. If used with an
inductive load, e.g., a relay, connect a diode in parallel with the load,
to protect against voltage transients.
Pin
Notes
1
2
Can be used to power auxiliary equipment.
Note: This pin can only be used as power out.
3–6
Digital input or Supervised input – Connect to pin 1 to activate, or
leave floating (unconnected) to deactivate. To use supervised input,
install end-of-line resistors. See connection diagram for information
about how to connect the resistors.
Digital output – Internally connected to pin 1 (DC ground) when
active, and floating (unconnected) when inactive. If used with an
inductive load, e.g., a relay, connect a diode in parallel with the load,
to protect against voltage transients.
55
Specifications
0 V DC
12 V DC
Max load = 25 mA
0 to max 30 V DC
0 to max 30 V DC, open drain,
100 mA
Specifications
0 V DC
12 V DC
Max load = 50 mA
0 to max 30 V DC
0 to max 30 V DC, open drain,
100 mA
Specifications
0 V DC
12 V DC
Max load = 50 mA
0 to max 30 V DC
0 to max 30 V DC, open drain,
100 mA