Download Print this page

B-K lighting HP2 Instructions Manual

Integral transformer - standard mr16 & par36/ar111

Advertisement

Quick Links

Standard Instructions
INSTRUCTIONS PERTAINING TO
A RISK OF FIRE, OR INJURY
TO PERSONS IMPORTANT SAFETY
INSTRUCTIONS
Lighted fixture is HOT!
WARNING - To reduce the risk of
FIRE OR INJURY TO PERSONS:
Turn
off/unplug
and
allow
replacing lamp/LED. Fixture gets HOT quickly!
Contact only switch/plug when turning on.
Do not touch hot lens, guard, or enclosure.
Keep fixture away from materials that may burn.
Do not operate the luminaire fitting with a missing or
damaged shield. Do not touch the source at any time.
Use a soft cloth or gloves. Oil from skin may cause
damage.
SAVE THESE INSTRUCTIONS
Proper soil preparation is recommended before installation. See the DIG-IT guide at
Optional Accessory Holder
Retaining Clip
Quick
Disconnect
HydroLock Plate
IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE THESE INSTALLATION
B-K LIGHTING
THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF B-K LIGHTING, INC. AND ITS RECEIPT OR POSSESSION DOES NOT CONVEY ANY RIGHTS TO REPRODUCE, DISCLOSE ITS CONTENTS, OR TO MANUFACTURE, USE OR SELL
ANYTHING IT MAY DESCRIBE. REPRODUCTION, DISCLOSURE OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF B-K LIGHTING, INC. IS STRICTLY FORBIDDEN.
Flammable
Warning
High Voltage
IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE ALL
• Product must be installed by a qualified person in a manner
consistent with its intended use and in compliance with the
National Electrical Code, Canadian Electrical Code, and all Local and
Provincial Codes.
• Follow product label information and instructions.
• Qualified Personnel with appropriate personal protective
to
cool
before
equipment must perform all servicing of this product.
• Before wiring to power supply and during servicing, turn off and
lock out power at fuse or circuit breaker before service.
• The use of accessory equipment not recommended by the
manufacturer or installed contrary to instructions may cause an
unsafe condition. The use of damaged components may cause an
unsafe condition and void product warranty.
IMPORTANT LISTINGS AND CERTIFICATIONS
· Suitable for wet locations · Suitable for recessed in ground locations
www.bklighting.com/collaterals/install/digit.pdf for more information.
(Vary by Product)
Thumbscrew
OptiLock Assembly
(Vary by Product)
Power Supply Bracket
(Power Supply Will Vary by Product)
Waterproof
Wire Connectors
INTEGRAL TRANSFORMER - STANDARD MR16 & PAR36/AR111
TOOLS
NEEDED:
Hot Surface
SAFETY AND INSTALLATION INSTRUCTIONS
Faceplate
O-Ring
Concrete Pour
Collar (CPC)
Stability Flange
Housing
INSTRUCTIONS
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • info@bklighting.com
1/8" Allen Wrench
Waterproof Wire Connectors
Level
Phillips Screwdriver
7/8" Hole Saw
Torque Wrench
• Do not block light emanating from product in whole or part, as
this may cause an unsafe condition.
• Never operate the fixture with missing or damaged lens.
Lens must be cleaned on regular basis.
• Entire fixture may become extremely hot. Do not touch hot
lens or fixture body.
• Replace LED assembly only with correct wattage and type of
power supply appropriate for LED assembly.
• All gaskets, o-rings and sealing surfaces must be kept clean
during installation and service; failure to do this may cause an
unsafe condition and void product warranty.
Soil Prep
Conduit
trench
A. Determine Soil Type by referencing
DIG-IT Guide.
B. Dig hole 18" wide and 20" deep.
Excavated
for Housing
C. Prep soil according to DIG-IT Guide.
RELEASE DATE
08/28/2023
HP2
18"
Dia.
Conduit
Trench
REFERENCE NUMBER
INS-2858-00

Advertisement

loading

Summary of Contents for B-K lighting HP2

  • Page 1 • info@bklighting.com THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF B-K LIGHTING, INC. AND ITS RECEIPT OR POSSESSION DOES NOT CONVEY ANY RIGHTS TO REPRODUCE, DISCLOSE ITS CONTENTS, OR TO MANUFACTURE, USE OR SELL ANYTHING IT MAY DESCRIBE. REPRODUCTION, DISCLOSURE OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF B-K LIGHTING, INC. IS STRICTLY FORBIDDEN.
  • Page 2: Housing Installation

    Top of grout mask should be flush with grade. IMPORTANT SAFETY INFORMATION LISTED ON REVERSE READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS B-K LIGHTING RELEASE DATE REFERENCE NUMBER 40429 Brickyard Drive • Madera, CA 93636 • USA 559.438.5800 •...
  • Page 3: Installation

    This step must be done as stated or you will void your warranty. IMPORTANT SAFETY INFORMATION LISTED ON REVERSE READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS B-K LIGHTING RELEASE DATE REFERENCE NUMBER 40429 Brickyard Drive • Madera, CA 93636 • USA 559.438.5800 •...
  • Page 4 INTEGRAL TRANSFORMER - STANDARD MR16 & PAR36/AR111 Standard Instructions 6. Lower transformer assembly into HP2 housing. Line up transformer plate to posts inside the HP2 8. Secure transformer plate into place by tightening housing with slots as shown. the three (3) #6-32 screws against the posts using a 5/64”...
  • Page 5 Do not use a power tool to install screws. Do not exceed 40 in-lbs. IMPORTANT SAFETY INFORMATION LISTED ON REVERSE READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS B-K LIGHTING RELEASE DATE REFERENCE NUMBER 40429 Brickyard Drive • Madera, CA 93636 • USA 559.438.5800 •...
  • Page 6 Do not use a power tool to install screws. Do not exceed 40 in-lbs. IMPORTANT SAFETY INFORMATION LISTED ON REVERSE READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS B-K LIGHTING RELEASE DATE REFERENCE NUMBER 40429 Brickyard Drive • Madera, CA 93636 • USA 559.438.5800 •...
  • Page 7 • info@bklighting.com THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF B-K LIGHTING, INC. AND ITS RECEIPT OR POSSESSION DOES NOT CONVEY ANY RIGHTS TO REPRODUCE, DISCLOSE ITS CONTENTS, OR TO MANUFACTURE, USE OR SELL ANYTHING IT MAY DESCRIBE. REPRODUCTION, DISCLOSURE OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF B-K LIGHTING, INC. IS STRICTLY FORBIDDEN.
  • Page 8 7/64” allen wrench. IMPORTANT SAFETY INFORMATION LISTED ON REVERSE READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS B-K LIGHTING RELEASE DATE REFERENCE NUMBER 40429 Brickyard Drive • Madera, CA 93636 • USA 559.438.5800 • FAX 559.438.5900...