MUST NEVER BE EXCEEDED, as it may damage and/or cause ruptures and/or leakages and/or even break the product, and present a potential hazard and danger to safety, health and/or property. Following are the technical data with respect to the installation of Gessi plumbing products. ► W orkingpressureshouldnotbelowerthan0,5bar(7,25psi)andnotbehigherthan5bar(72Psi).In case of higher working pressure use a pressure reducer valve.
Page 3
Ci-dessous nous indiquons les données techniques concernant l’installation des produits sanitaires Gessi. ► L apressiondeservicenedoitpasêtreinférieureà0,5bar(7,25psi)etsupérieureà5bar(72Psi).En cas de pressions de service plus hautes utiliser une soupape de réduction de la pression.
Page 4
1 - ¡CUIDADO!! LES ROGAMOS QUE TENGAN EN CUENTA QUE NUNCA la presión y/o la temperatura máximaaconsejadaNOTIENEQUESERSUPERADA,yaquepodríadañary/ocausarrupturasy/o pérdidasy/oaveríasdelproductoy,porlotanto,representarunriesgoyunpeligropotencialpara la seguridad, la saludad y/o la propiedad. A continuación Les proporcionamos los datos técnicos relativosalainstalacióndelosproductosdegriferíaGessi. ► L apresióndeejercicionotienequeserinferiora0,5bar(7,25psi)ysuperiora5bar(72Psi).Encaso depresionesdeejerciciomayores,utilicenunaválvuladereduccióndelapresión. ►Presiónmáximadeensayodurantelainstalación:8bar(116psi). ► E vitengrandesdiferenciasdepresiónentrelaalimentacióndelaguafríayaquelladelaguacaliente. Lasdiferenciasdepresión,elaguaconunalatocontenidomineralylassustanciasjabonosaspueden...
Page 5
PRE-INSTALLATION INFORMATION - PRÉALABLES - PRELIMINARES Before installation and setting to work Attention! The feeding pipes have to be rinsed thoroughly before the installation of the mixer, so that no shavings, welding or hemp residual or other dirt can be found in the pipes. Foreign bodies can enter the mixer through the rinsed pipes or the general water plant and could damage the washers/ring washers.
Page 6
PRE-INSTALLATION INFORMATION - PRÉALABLES - PRELIMINARES Package content: 1-Built-in body Contenu de l’emballage: 1-Corps encastrement Contenido del embalaje: 1-Cuerpo por empotrar Tools for insTAllATion - ouTils néCessAires Pour l’insTAllATion - HerrAmienTA neCesAriA PArA lA insTAlACión 3/4” [19 mm]...
INSTALLATION - INSTALLATION - INSTALACIÓN fig. 1 ColD fig. 2 3/4” nPT - m 3/4” nPT - m fig. 3 Level of the finished floor Plan du sol terminé Plano del piso terminado...
Page 8
INSTALLATION - INSTALLATION - INSTALACIÓN fig. 4 ColD fig. 5 fig. 6 use hemp or teflon employer chanvre ou teflon usarcáñamooteflon...
Page 9
INSTALLATION - INSTALLATION - INSTALACIÓN fig. 7 oPen PRESSURE TEST fig. 8 3/4” fig. 9 fig. 10 [19 mm] G 1/2”...
Page 10
INSTALLATION - INSTALLATION - INSTALACIÓN fig. 11 Not supplied Non fournie Excluida del suministro fig. 12 oPen fig. 13 fig. 14 3/4” [19 mm]...
Need help?
Do you have a question about the 24996 and is the answer not in the manual?
Questions and answers