Tap Water pressures. Air Requirements 70-100 psi clean dry shop air The power unit on the FT1312 Hose Proof Stand operates on the simple Test Pressure 20,000 psi maximum principle of a pressure magnification through differential areas in which Tooling...
Page 4
Open the cabinet and remove the umbilical hose and test tooling from the tested assembly. Drain the remaining water from the tested assembly. It is recommended that all hose assemblies be blown dry with compressed air. 4 | Danfoss FT1312 Hose Proof Test Stand Operators Manual | 2023.06. AQ452153740268en-010101...
2. Check high pressure dump valve is closed. Bleed air from test sample. Supply air not connected or air shut-off valve not open. Power unit not functioning when air regulator adjusted. 5 | Danfoss FT1312 Hose Proof Test Stand Operators Manual | 2023.06. AQ452153740268en-010101...
Page 6
2046-24-24S & 2082-24S 2022-8-8S - 32 2040-24-32S 2040-12-16S & 2040-16-20S & 2046-32-32S & 2082-32S 2040-20-24S & 2022-8-8S Adapters are available for other hose fittings styles. Contact Danfoss 6 | Danfoss FT1312 Hose Proof Test Stand Operators Manual | 2023.06. AQ452153740268en-010101...
Page 8
Danfoss FT1312 Hose Proof Test Stand Operators Manual FT1312 Hose Proof Test Stand 8 | Danfoss FT1312 Hose Proof Test Stand Operators Manual | 2023.06. AQ452153740268en-010101...
Page 9
Lid, Gas Spring Bracket FT1312-3-18 Gas Spring Bracket Mounting Plate FT1312-3-19 1/-20 x 1.00 Flat Hd Soc Cap Screw FT1312-3-20 1/4-20 Stainless Steel Nut FT1312-3-21 10MM Ball Stud 9 | Danfoss FT1312 Hose Proof Test Stand Operators Manual | 2023.06. AQ452153740268en-010101...
Page 10
Danfoss FT1312 Hose Proof Test Stand Operators Manual FT1312 Power Unit 10 | Danfoss FT1312 Hose Proof Test Stand Operators Manual | 2023.06. AQ452153740268en-010101...
O-Ring seaI proof test adapters POWER UNIT The power unit of the FT1312 tester is a compact, economical air driven hydraulic pump. It will provide sufficient hydraulic pressure to proof test any Danfoss hose assembly. The pump operates on a simple principle of pressure magnification through use of differential areas in which a relatively large air operated piston drives a smaller piston to provide fluid flow at high pressures.
Page 13
CAUTION: High pressure water can be dangerous. Read all Operat- FT1236-1-13 -20 37˚ JIC Swivel ing and Safety Instructions in Owner’s Manual before attempting to FT1236-1-14 -24 37˚ JIC Swivel operate. 13 | Danfoss FT1312 Hose Proof Test Stand Operators Manual | 2023.06. AQ452153740268en-010101...
Page 14
Phone: +86 21 3418 5200w Danfoss can accept no responsibility for possible errors in catalogs, brochures, and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequent changes being necessary in specifications already agreed.
Need help?
Do you have a question about the FT1312 and is the answer not in the manual?