FW-RC4-AC v2
Transmitter
for ø60 flush-mounted box
Do not dispose of this device to thrash with other unsorted waste! In accordance
with the Waste Electrical and Electronic Equipment Act any household electro-waste
can be turned in free of charge and in any quan� ty to a collec� on point established for
this purpose, as well as to the store in the event of purchasing new equipment (as per
the old for new rule, regardless of brand). Electro-waste thrown in the trash or aban-
doned in the bosom of nature pose a threat to the environment and human health.
Descrip� on of the system
F&Wave is a family of wireless devices controlled by radio with a range of up to 100
meters*. The receivers are available in either a DIN-rail mounting version (housing
1S) or a ø60 flush-mounted version. The transmitters are available as handheld remo-
te controllers or as a flush-mounted version. The receivers relay control signals. The
device that receives a control signal from the transmitter will automatically send it
forward, which allows to increase the range of the remote control.
* Range of up to 100 meters in open space without any interfering factors. In building conditions and in the presence of
interference sources (power lines, transmitters, etc.) the actual range may be smaller.
F&F Filipowski L.P.
Konstantynowska 79/81, 95-200 Pabianice, Poland
phone/fax (+48 42) 215 23 83 / (+48 42) 227 09 71
ww.fif.com.pl; e-mail: biuro@fif.com.pl
- 1 -

Advertisement

loading

Summary of Contents for F&F FW-RC4-AC v2

  • Page 1 Konstantynowska 79/81, 95-200 Pabianice, Poland phone/fax (+48 42) 215 23 83 / (+48 42) 227 09 71 ww.fif.com.pl; e-mail: biuro@fif.com.pl FW-RC4-AC v2 Transmitter for ø60 flush-mounted box Do not dispose of this device to thrash with other unsorted waste! In accordance with the Waste Electrical and Electronic Equipment Act any household electro-waste can be turned in free of charge and in any quan�...
  • Page 2 Installation of this device should be carried out by a qualified installer after re- ading this manual. Dismantling the casing of the device will automatically void the warranty. Before starting the assembly, make sure that the connecting wires are not live. Conditions of storage, transport and use affect the proper operation of the device.
  • Page 3: Wiring Diagram

    Descrip� on of the device Wiring diagram L – power supply L N – power supply N S1 – control input S2 – control input S3 – control input S4 – control input Control input does not work with backlighted buttons. - 3 -...
  • Page 4 Pairing After you successfully connect the receiver, press and hold the PROG button until the device switches ① on the output circuit and the communication LED goes off. Press the selected button connected to the flush- ② -mounted transmitter. If the pairing is correct, the output circuit will be momentary switched off ③...
  • Page 5 Bu� on confi gura� on Mode Input The functions performed by the inputs depend on the type of buttons connected and the type of receiver to be controlled. Buttons can be connected to the transmitter: monostable (momentary) enabling the realisation of S1, S2, S3, S4, ON and OFF ...
  • Page 6 Bu� on confi gura� on cont. OFF function A short press on the monostable button will: switching off the relay receiver (*),  lowering a roller shutter on roller shutter controllers (*),  switching off the light in lighting dimmers. ...
  • Page 7 Devices of the F&Wave system Battery transmitters Type Product Flood sensor FW-FS1 Remote control FW-KEY, FW-RC4, FW-RC10 FW-WS1, FW-WS2, FW-WS3 Wall button FW-WSO1, FW-WSO2, FW-WSO4 Flush-mounted box ø60 FW-RC5 AC transmitters Type Product FW-GS1, FW-GS2, FW-GS4 Flush-mounted box ø60 FW-RC4-AC Receivers Function Flush-mounted box ø60...
  • Page 8: Warranty

    Technical data power supply 85÷265 V AC/DC control inputs 85÷265 V AC; <1 mA power consumption operating mode 0.5 W standby 0.25 W radio frequency 868 MHz working temperature -25-50°C terminal 2.5 mm² screw terminals tightening torque (max) 0.4 Nm mounting �60 flush-mounted box dimensions...