,for RAK-50PED only
(1) Pressing the "POWERFUL" button will reduce the temperature setting by PWSFTC.
(2) The powerful operation is for 20 minutes after setting.
(3) Operation is continued forcibly thermo-ON for 20 minutes after the powerful operation is finished.
(4) Pressing the "START/STOP" button and "POWERFUL"button during powerful operation wil
cancel the powerful operation.
(5) If the sleep timer is set during powerful operation, the powerful operation will be canceled.
(6) When the powerful operation is set, the fan speed will be set to "HIGH" and the compressor's maximum
speed will be set to CMAX2 during powerful operation. The compressor's lower limit speed is CKYMIN_PW.
(7) The fan speed increases by FNUPPW_C.
(8) After the powerful operation is ended, the system automatically operates with the previous settings used
before the powerful operation.