Download Print this page

VADO IND-Z143 Series Installation Manual page 6

1 way wall mounted concealed stop valve

Advertisement

Installation
Outlet arrow on
valve
Outlet
After removing the blanking plug and adding the outlet adaptor to the ZON-128 connect
the water supply to the right inlet of the valve. Connect the outlet (arrow on valve) to the
desired channel e.g. shower head and handset.
Tiling guide
Tile around the tiling guide as tight as possible. Keep the final finished wall surface
between the min and max marks.
10
Installation
Inlet from
ZON-128
Remove the 2 screws using the suitable hex key provided with the ZON-128 and pullout
the tiling guide.
Slide the collar into the hole. Line up the holes and secure in position using the screws
from the previous step.
Screws
Tiling guide
Collar
Screws
11