Fujitsu AOUG12LZAH1 Service Manual page 115

Hide thumbs Also See for AOUG12LZAH1:
Table of Contents

Advertisement

¢ Compressor temperature thermistor
Temperature °F (°C)
-22.0 (-30.0)
-12.0 (-25.0)
-4.0 (-20.0)
5.0 (-15.0)
14.0 (-10.0)
23.0 (-5.0)
32.0 (0.0)
41.0 (5.0)
50.0 (10.0)
59.0 (15.0)
68.0 (20.0)
77.0 (25.0)
86.0 (30.0)
95.0 (35.0)
104.0 (40.0)
113.0 (45.0)
122.0 (50.0)
131.0 (55.0)
140.0 (60.0)
149.0 (65.0)
158.0 (70.0)
167.0 (75.0)
176.0 (80.0)
185.0 (85.0)
194.0 (90.0)
203.0 (95.0)
212.0 (100.0)
221.0 (105.0)
230.0 (110.0)
239.0 (115.0)
248.0 (120.0)
6-2. Outdoor unit
Resistance (kΩ)
1,013.11
729.09
531.56
392.31
292.91
221.09
168.60
129.84
100.91
79.12
62.55
49.84
40.01
32.35
26.34
21.58
17.79
14.75
12.30
10.32
8.70
7.36
6.27
5.36
4.60
3.96
3.43
2.98
2.60
2.27
2.00
- (03-79) -
Voltage (V)
0.06
0.09
0.12
0.16
0.21
0.28
0.36
0.46
0.57
0.71
0.86
1.03
1.23
1.43
1.65
1.88
2.11
2.34
2.57
2.79
3.00
3.19
3.37
3.54
3.69
3.83
3.96
4.07
4.17
4.26
4.33
6. Thermistor resistance values