11. Safety devices
Type of
protection
Circuit
Current fuse (Main PCB)
protection
Fan motor
Thermal protection program
protection
Thermal protection program
(Compressor temp.)
Compressor
Thermal protection program
protection
(Discharge temp.)
Thermal protection program
(Outdoor temp.)
(Only in COOL and DRY mode)
Protection form
Activate
Reset
Activate
Reset
Activate
Reset
Activate
Reset
AOUG09LZAH1 AOUG12LZAH1 AOUG15LZAH1
250 V, 15 A
257±18 °F (125±10 °C)
Fan motor stop
248±18 °F (120±10 °C)
Fan motor restart
226 °F (108 °C)
Compressor stop
After 3 minutes, and 176 °F (80 °C) or less
Compressor restart
230 °F (110 °C)
Compressor stop
After 7 minutes
Compressor restart
Compressor stop
14 °F (-10 °C)
Compressor restart
- 69 -
Model
250 V, 20 A
250 V, 5 A
250 V, 3.15 A
5 °F (-15 °C)
11. Safety devices