If your projector is WHITE, follow these instructions:
1
Turn off the projector and unplug the power cord.
2
Wait 60 minutes to allow the projector to cool thoroughly.
3
Remove the lamp door, located on top of the projector, by removing the screw
on the side of the lamp door, sliding the door right, and lifting the lamp door
off.
4
Remove the screws that attach the light blocking plate and lamp housing to the
projector. NOTE: If the projector is installed on a ceiling mount, be careful not
to drop the lamp module once the captive screws are loosened.
5
Remove the light blocking plate.
6
Carefully lift the lamp straight up, off of the alignment pins; being careful not to
pinch the lamp connector. Dispose of the lamp in an environmentally proper
manner.
7
Install the new lamp module, aligning the pins properly. Be careful not to pinch
the lamp connector.
8
Replace the light blocking plate.
9
Tighten the screws. (NOTE: If the pins have not been aligned properly, the
screws will not tighten securely.)
10
Replace the lamp door by (a) putting the lamp door down and (b) sliding it
until it locks.
11
Replace the lamp door screw and tighten securely.
12
Plug in the power cord and press the Power button to turn the projector back
on.
13
To reset the lamp hour timer, navigate to the Advanced Menu > Status/Service
menu and select Reset Lamp Hours....