Desa CGDV32NR Owner's Operation And Installation Manual page 5

Direct-vent fireplace
Table of Contents

Advertisement

PRE-INSTALLATION
PREPARATION
Continued
CLEARANCES
Minimum clearances to combustibles for the fireplace are as follows:
*Back and sides
Perpendicular walls
Floor
Ceiling to louver opening 42" (1067mm)
Front
Top of Standoffs
Vent
Combustible material with a maximum thickness of 5/8" may be
flush with the top front of fireplace.
* For back and sides of fireplace, do not pack with insulation or
other materials. Zero inch clearance to combustible materials are
for framing purpose only.
NOTICE: This fireplace is intended for use as supple-
mental heat. Use this fireplace along with your primary
heating system. Do not install this fireplace as your
primary heat source. If you have a central heating
system, you may run system's circulating blower
while using fireplace. This will help circulate the heat
throughout the house. In the event of a power outage,
you can use this fireplace as a heat source.
FRAMING AND FINISHING
Figure 4 shows typical framing of this fireplace. Figure 5 shows fram-
ing for corner installation. All minimum clearances must be met.
32
/
3
8
34
5
/
"
8
Figure 4 - Framing Clearances for Installation Against an
Exterior Wall
116646-01B
0"/mm
6" (152mm)
0"/mm
36" (914mm)
0"/mm
(See venting instructions for
specific venting clearances.)
"
17" Horizontal Vent
20" Vertical Vent
www.desatech.com
PRE-INSTALLATION PREPARATION
For available accessories for this fireplace, see Accessories on page
37. If you are using a separate combustible mantel piece, refer to
Figure 6 for proper installation height. You can install noncombus-
tible mantels at any height above the fireplace.
Note: Noncombustible mantels may discolor!
13
/
"
5
B
8
28
/
"
1
A
2
9
7
/
"
E
8
Figure 5 - Framing Clearances for Corner Installation
A
B
C
D
Top of Louver Opening
Ref. Mantel Depth Ref.
Mantel from Top
of Louver Opening
1
14" (356mm)
A
16" (406mm)
2
12" (305mm)
B
14" (356mm)
3
10" (254mm)
C
12" (305mm)
4
8" (203mm)
D
10" (254mm)
5
6" (152mm)
E
8" (203mm)
6
4" (101mm)
F
6" (152mm)
7
2" (51mm)
G
4" (101mm)
Figure 6 - Clearances for Combustible Mantels
Clearances
Framing and Finishing
9
D
/
"
1
39
C
/
"
2
3
8
34
3
/
"
F
8
34
/
"
5
8
G
54
/
"
1
H
8
1
2
3
Wall
4
5
6
E
7
F
G
5 5
Nailing
Nailing Tabs