Machine Usage
⚠ CAUTION
To reduce the risk of injury or product damage, read this entire operating manual, with
particular emphasis on the Safety and Preparation sections (Page 3-8), prior to operating the G5Twin.

STANDARD RECOVERY PROCEDURE

1. Setup the G5Twin as shown in Diagram 4 (below). Make sure that all connections are tight.
A. Connect a Valve Core Removal Tool to othe AC/R System Liquid Port.
B. Connect a Valve Core Removal Tool to othe AC/R System Vapor Port.
C. Connect the AC/R System Liquid Port to the Y-Connector.
D. Connect the AC/R System Vapor Port to the Y-Connector.
E. Connect the Y-Connector to the G5Twin input port.
F. Connect the G5Twin output port to the Vapor Port on the Recovery Cylinder.
Diagram 4
Recover into the Vapor Port of the Recovery
Cylinder for faster recovery.
OPTIONAL: To improve tank cooling, start
with the recovery cylinder upside down,
and flip the tank right-side up near the end
of the vapor recovery.
2. Open both valves on the G5Twin and open the Recovery Cylinder Vapor Port.
Make sure to completely open the Recovery Cylinder valve to prevent "output restrictions" (See Tip #1,
Page 14).
3. Turn on the G5Twin. The compressor and fan should start.
4. Slowly open the Valve Core Removal Tool ball valve on the liquid port.
Removing liquid first will keep recovery time to a minimum, and improve cooling properties of the
recovery cylinder. NOTE: Overheating or slow recovery speeds may be caused by "input restrictions" (See
Tip #2, Page 14).
5. When all the liquid has been removed, completely open the Valve Core Removal Tool ball valve on the
vapor port. Both sides should now be fully open to maximize vapor flow.
6. Continue to run the G5Twin until the EPA-required vacuum is achieved.
7. Close both Valve Core Removal Tool ball valves.
8. Turn o the G5Twin, then close the output valve on the G5Twin.
9. Close the G5Twin input valve, close the valves on the Recovery Cylinder, and disconnect the hoses.
B
D
A
9
E
F
C
G5TWIN OPERATION MANUAL
© 2022 APPION INC. - ALL RIGHTS RESERVED

Hide quick links: