Voltmeter Characteristics:

VADER User Guide (MAN405)
Page 6 of 7
• High Voltage Isolation for Operator Safety : Tested to 1kV steady-state/15kV transient voltage levels
(designed for higher voltage level isolation) – operator isolated from power supply
• Non-Saturating : Voltmeter will not saturate on 5.7VDC and higher ranges with superimposed AC
signals up to 120VAC (for readings up to approximately 50% of full scale at 60Hz) and/or inductive spikes
up to 2kV appearing at the input terminals
• Extensive Ranges : Various DC Ranges (40mV full scale to 570V full scale) plus 4V, 40V, and 400V AC
Ranges. All DC Ranges have <80ms response times for accurate On/Off pair readings during fast current
Power Source:
interruption cycling (for example, 700ms ON / 300ms OFF).
• 21700 Lithium Ion rechargeable battery
• Interior battery charging port
• Re-chargeable battery lasts approximately 8 hours with continuous usage
Communication with Tablets/Phones via WPAN technology:
• Battery easily replaced in the field
• Android™ compatible
Connectors:
• Connection status indicator, LED, on case exterior
• 5-pin connector for optional push-button data-probe triggering of readings
Integrated Sub-meter GPS System:
• Two shrouded banana jacks (one red/one black) – 1,000V; CAT III (IEC 61010 rating)
Environmental:
• Internal GPS antenna
Temperature Ranges:
• IP65 Rated
• Operating Range: 32°F to 104°F (0°C to 40°C) • Battery Charging Range: 32°F to 104°F (0°C to 40°C)
Case Dimensions (approximate):
• 5-7/8" long x 3.5" wide x 1.75" high
Weight:
• 0.85lb