Summary of Contents for ROWAN ELECTRIC APPLIANCE NCA Series
Page 1
WINDOW AIR CONDITIONER USER MANUAL MODEL: NCA series Thanks for choosing this Window Air Conditioner. This Manual will provide you with valuable information necessary for the proper care and maintenance of your new product. Please take a few moments to thoroughly read the instructions and familiarize yourself with all the operational aspects of your new Window air conditioner.
SAFETY INSTRUCTION Your safety and the safety of others are very important. We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages. This is the safety alert symbol. This symbol alerts you to potential hazards that can hurt you and others. All safety messages will follow the safety alert symbol, either the word “DANGER,”...
Page 4
Disconnect power before servicing. Disconnect power before cleaning. NOTE: Turning off power by pressing the Power button does NOT disconnect the appliance from the power supply. Do not install or use the air conditioner in any area where the atmosphere contains combustible gases or where the ...
Page 5
Do not apply any permanent inductive or capacitance loads to the circuit without ensuring that this will not exceed the permissible voltage and currently permitted for the equipment in use. Intrinsically safe components are the only types that can be worked on while living in the presence of a flammable atmosphere. The test apparatus shall be at the correct rating.
Page 6
Before attempting the procedure ensure that: --mechanical handling equipment is available, if required, for handling refrigerant cylinders; --all personal protective equipment is available and being used correctly; --the recovery process is supervised at all times by a competent person; --recovery equipment and cylinders conform to the appropriate standards. Pump down refrigerant system, if possible.
Page 7
pour un examen, une réparation ou un réglage. Débranchez l'alimentation avant l'entretien. Débranchez l'alimentation avant de nettoyer. REMARQUE: couper l'alimentation en appuyant sur le bouton d'alimentation ne déconnecte PAS l'appareil de l'alimentation électrique. N'installez pas et n'utilisez pas le climatiseur dans une zone où l'atmosphère contient des gaz combustibles ou où ...
Page 8
au cours desquelles un réfrigérant inflammable peut éventuellement être libéré dans l'espace environnant. Avant le début des travaux, la zone autour de l'équipement doit être inspectée pour s'assurer qu'il n'y a pas de risques d'inflammabilité ou d'inflammation. Des panneaux « interdiction de fumer » doivent être affichés. Assurez-vous que la zone est à...
Page 9
– Assurez-vous que le système de réfrigération est mis à la terre avant de charger le système avec du réfrigérant. – Étiquetez le système lorsque la charge est terminée (si ce n'est déjà fait). – Un soin extrême doit être pris pour ne pas trop remplir le système de réfrigération. Avant de recharger le système, il doit être testé...
reste pas dans le lubrifiant. Le processus d'évacuation doit être effectué avant le retour du compresseur aux fournisseurs. Seul le chauffage électrique du corps du compresseur doit être utilisé pour accélérer ce processus. Lorsque l'huile est vidangée d'un système, elle doit être effectuée en toute sécurité. LIRE ET CONSERVER CES INSTRUCTIONS PARTS IDENTIFICATION Air outlet...
INSTALLATION REQUIREMENTS NOTE: Before using the air conditioner, keep the unit upright for at least four hours. This air conditioner is a window air conditioner, which can only be installed and used on the window. During the process of moving and handling, make sure that the machine is in an upright state. Do not install or use this machine in a bathroom or in a humid environment.
Page 12
ELECTRICAL REQUIREMENTS WARNING Electrical Shock Hazard Plug into a grounded 3-prong outlet only. Do not remove the ground-prong from the power cord plug. Do not use any adapter. Do not use any extension cord. Failure to do so can result in injury, fire or electrical shock. POWER SUPPLY CORD Wiring Requirements 115 Volt, 60Hz, 15-amp fused grounded 3-prong outlet.
INSTALLATION INSTRUCTIONS STEP 1 - UNPACK AIR CONDITIONER WARNING Excessive Weight Hazard Two or more people are required to move and install the air conditioner. Failure to do so may result in back or other injuries. Remove packaging materials. Save the carton and the foam packaging for storing the air conditioner when not in use. NOTE: There are NO packing materials inside the air conditioner to remove—Do Not open the cabinet.
STEP 5 – ATTACH FOAM SEALER Measure the distance between the unit and the window sash. Cut the foam sealer to the corresponding length by using a utility knife. Remove adhesive from foam sealer and put foam (adhesive-side) against the edge of the unit and insert the other side into the window.
CONTROL PANEL BUTTONS A. POWER BUTTON Turns ON/OFF power to the air conditioner. NOTE: Turning off power by pressing the Power button does NOT disconnect the appliance from the power supply. B. FILTER RESET BUTTON Press this button when the filter indicator is on. The light will illuminate every 250 hours of operation as a reminder to clean the filter.
2. Press the Up Arrow or Down Arrow buttons to select the Temperature. NOTE: The temperature cannot be set when the air conditioner is in Dry, Fan, Auto or Sleep mode. NOTE: The Up Arrow and Down Arrow buttons, when pressed at the same time, allow you to select between displaying the temperature in ºC and ºF.
Page 17
When My Temp mode is activated, double hyphen sign "--" will flash 3 seconds on digital display. The air conditioner will cool the area depending on the location and set temperature of the remote control. Take the remote control with you so the air conditioner cools the room to your location. ENERGY SAVER BUTTON Press this button to turn on Energy Saver mode.
DRAIN THE INTERNAL WATER INDOOR DRAINAGE Put the water container under the water outlet on the left side of the unit. Unplug the water plug, the water will automatically flow into the water container. When the water drainage is finished, re-plug the water stopper. NOTE: Please properly protect the water plug.
FILTER CLEANING Clean the filter once every two weeks, or it would influence the unit function if the filter is clogged with dust. Hold the two sides of the air inlet grille with your hands, and open the grille with slight force in the correct direction.
Keep unit running in fan mode for 4 hours to dry the inside of unit completely to prevent from going moldy. Turn off the unit, pull out plug. Keeping a firm grip on air conditioner, lift up and remove the air conditioner from the window and sill. NOTE: When loosening the support knob, please hold the unit tightly to prevent the whole unit from turning to the outside of the window.
Page 21
TROUBLE CAUSE SOLUTION Contact customer service & repair “E1” code displays Room temperature sensor failure center Contact customer service & repair “E2” code displays Tube temperature sensor failure center After thawing, the function will be “E4” code displays Anti-frozen protection is activated. restored automatically.
Page 22
213-4467172 661-4358826 (8:30am - 5:30pm P.S.T.) SE REQUIERE PRUEBA DE COMPRA CON FECHA PARA SERVICIO BAJO GARANTÍA. Address: ROWAN ELECTRIC APPLIANCE LLC 28407 Ascent Way, Santa Clarita, CA 91350 Phone: 213-4467172 or 661-4358826...
Need help?