Set Over Charge Amount - Matco Tools AC880 Operation & Maintenance Manual

Refrigerant handling system
Table of Contents

Advertisement

W E I G H T =
X X . X
A U T O M A T I C
?
>>>>>
ENTER
W E I G H T =
X X . X
S E T U P
?
Calibration Switch
W E I G H T =
X X . X
C H A R G I N G
>
O V E R
C H A R G E
A M O U N T =
X . X X
><
ENTER

SET OVER CHARGE AMOUNT

L B
#
1.
Remove the front panel of the AC880.
2.
Set up the AC880 as shown on Page 4 and then turn the Main Power Switch
ON. Refer to the figure below to locate the Access Hole (on the metal circuit
board cover) to the Calibration Switch.
L B
3.
Remove the plastic Calibration Tool from the mounting hole of the circuit board
#
cover.
4.
Using the Keypad, press the "Up Arrow" key five times to display "WEIGHT=
XX.X LB" "SETUP? # ".
L B
5.
GENTLY press the Calibration Switch with the Calibration Tool. The Display will
read "WEIGHT= XX.X LB" "CHARGING".
6.
Press the "Up Arrow" key. The Display will read "OVER CHARGE" "AMOUNT=
X.XX KG # ".
7.
Press the "Up Arrow" key to change the value of the field. Press the "Right
Arrow" key to change to a different field. The value entered will be stored until
this procedure is run again and a new value is entered. Press the ENTER key
K G #
to accept the value. The Display will then return to the Main Menu.
Note:
8.
Replace the front panel of the AC880.
Calibration Tool Part No. 360-81214-00
Get other manuals https://www.bkmanuals.com
1 oz = 0.02835 Kg
1 Lb = 0.45359 Kg
Page 13