  • Page 1 Wired Touch Panels User Manual 24.06.2019...
  • Page 2 32 License Ethernet Direct PC Connection 33 s oftWare and IrMWare ICense 19 W IndoWs oCal etWork ettIngs WiredTouchPanels_UserManual 24.06.2019 Copyright © CUE, a.s., Praha, Czech Republic 1990 - 2017 All rights reserved. Specifications are subject to change without prior notice.
  • Page 3: Models And Accessories

    Web server and Admin Web for setup through a standard web browser Programming All touch panels have to be programmed using Cue Visual Composer. These models are not compatible with Cue System Director. © CUE, a.s. | All Rights Reserved.
  • Page 4: Box Contents

    Touch panel touchCUE-5-B Touch panel touchCUE-7-B Touch panel touchCUE-10-B Touch panel touchCUE-12-B Wall Mount Adapter incl. screws 1 PoE Adapter PoE+ Adapter Power cable Ethernet cable Cleaning tissue Quick Start Declaration of Conformity Warranty Conditions © CUE, a.s. | All Rights Reserved.
  • Page 5 Touch panel touchCUE-12-M Back cover incl. fixing screws PoE Adapter PoE+ Adapter Power cable Ethernet cable Squeegee Adhesive cover foil Adhesive tapes Set of cable bushings Cleaning tissue Quick Start Declaration of Conformity Warranty Conditions © CUE, a.s. | All Rights Reserved.
  • Page 6: Specifications

    Included accessories PoE power supply, PoE power supply, PoE power supply, PoE+ power supply, Ethernet cable, Ethernet cable, Ethernet cable, Ethernet cable, Wall mounting adapter Wall mounting adapter Wall mounting adapter Wall mounting adapter © CUE, a.s. | All Rights Reserved.
  • Page 7 Weight 0.8 kg 1.1kg 2.2 kg Included accessories PoE power supply, Ethernet cable PoE power supply, Ethernet cable PoE+ power supply, Ethernet cable Available extension NFC Module | CS0579 NFC Module | CS0579 © CUE, a.s. | All Rights Reserved.
  • Page 8 268 mm 121 mm Microphone Front view Side view LED indicators Proximity sensor transmitter Light sensor LCD display with touch sensor Proximity sensor receiver Network connector Integrated tabletop stand Speakers System Default button © CUE, a.s. | All Rights Reserved.
  • Page 9 Fixing screw Front View Rear View Proximity sensor receiver Proximity sensor transmitter Light sensor LCD display with touch sensor Button System Default 136 mm Network connector Top View Microphone Wall adapter 88 mm © CUE, a.s. | All Rights Reserved.
  • Page 10 Proximity sensor transmitter LED indicators LCD display Light sensor with touch sensor Proximity sensor receiver 268 mm Wall adapter 150 x 160 37 mm Top view Microphone Fixing screw Bottom view Speakers Network connector © CUE, a.s. | All Rights Reserved.
  • Page 11 Proximity sensor receiver 199 mm Ethernet cable bushing Hole for network connector Top view Installation on the wall 23 mm Microphone Fixing screw Fixing screw Wall Panel Bottom view Ethernet cable bushing © CUE, a.s. | All Rights Reserved.
  • Page 12 Side View Front View Side View Rear View 75 mm LCD display with touch sensor Proximity sensor transmitter Hole 320 mm for network connector Ethernet cable bushing Ethernet cable bushing Top View Microphone © CUE, a.s. | All Rights Reserved.
  • Page 13: Proximity Sensor

    Two programmable RGB LED indicators are located on the left and right side of touch panel enclosure. Special command is available in XPL programming language to control indicators. For touchCUE-10, touchCUE-10-B and touchCUE-10-M only. Touch-screen display Touch-screen display with active matrix color LCD and resistive membrane touch overlay.
  • Page 14 1.7 mm Max. Ø 5.5 mm 2. Connect network cable and put the touch panel on the wall adapter. 3. Carefully tighten the fixing screw to fix touch panel on the wall. © CUE, a.s. | All Rights Reserved.
  • Page 15 Covers are cover - installed on the wall. fixed with adhesive tape. Using Screws © CUE, a.s. | All rights reserved. | Published 09.11.2016 www.touchone.eu | sales@cuesystem.com | support@cuesystem.com Multisurface models installation - using screws Step 1 Step 2...
  • Page 16: C Leaning The T Ouch P Anel

    2. Spray a small amount of the cleaning solution onto one of the cloths. 3. Clean the touch panel overlay with the damp cloth. 4. Wipe the touch panel overlay with the dry cloth. © CUE, a.s. | All Rights Reserved.
  • Page 17 TX_D1+ and PoE White / Orange TX_D1- and PoE Orange RX_D2+ and PoE White / Green Blue PoE +/- 48 V White / Blue RX-D2- and PoE Green White / Brown PoE Common Brown © CUE, a.s. | All Rights Reserved.
  • Page 18: Direct Pc Connection

    LAN port of your computer. 3. Attach power supply to the PoE (PoE+) adapter. Power supply PoE Adapter for 7” models PoE+ Adapter for 12” models Ethernet cable straight-through Ethernet cable crossed-over © CUE, a.s. | All Rights Reserved.
  • Page 19: Etwork S Ettings

    192.168.1.1 (or other address different Properties. from 192.168.1.127 and from 192.168.1.128) and Subnet mask to 255.255.255.0. Leave other options 2. Select Internet Protocol (TCP/IP) and click Properties unchanged and click OK. button. © CUE, a.s. | All Rights Reserved.
  • Page 20: Using Cue Visual Composer

    Wired Touch Panels - User Manual pplICatIon oWnload Overview User control application is dedicated to control and it is programmed by Cue Visual Composer programming tools. Using Cue Visual Composer Steps are Connect touch panel to your computer as described in chapter PC Connection.
  • Page 21: Using Admin Web

    6. Use button Export All... to export application and store it in file *.cvca. Run the Internet browser on your PC and type in the same touch panel IP address as you see in Cue Visual Composer project, window Properties / IP address.
  • Page 22 Use Internet clock Not changed Primary NTP server Empty Not changed Secondary NTP server Empty Not changed Applications Empty Not changed File storage Empty Not changed System Firmware Current version Not changed Password Empty Empty © CUE, a.s. | All Rights Reserved.
  • Page 23: Access On Screen Display

    IP address automatically from DHCP server. For it select Yes in the field Use DHCP. IP address (or Magic name, see chapter Admin Web) must be entered into the Cue Visual Composer program written for your specific application. For control systems with more than one unit, a unique IP address must be given to each CUEunit.
  • Page 24 Active application starts automatically after switch on the unit. The running application can be stopped via the Stop button. Files are uploaded from a personal computer to the touch panel using Cue Visual Composer software or using Admin Web.
  • Page 25: Access Admin Web

    The default password is empty. You can find CUEunits and their IP addresses on the network with Cue Visual Composer / Tools / Scan CUEunits... You can open Internet browser with admin web of given unit by doubleclick on the line with this unit.
  • Page 26 DHCP server. For it check the checkbox Use DHCP to obtain IP address. IP address or Magic name must be entered into the Cue Visual Composer program written for your specific application. For control systems with more than one CUEunits, a unique IP address must be given to each CUEunit.
  • Page 27 NTP servers. Use the Primary NTP server and Secondary NTP server boxes for this purpose. Be sure to click the Apply button for any changes to the internet clock to become effective! © CUE, a.s. | All Rights Reserved.
  • Page 28: File Storage

    Wired Touch Panels - User Manual Applications This page is used for uploading compiled Cue Visual Composer programs to your CUEunit. All uploaded applications are listed on this page, along with their file properties: file name/file size/date. The CUEunit has a generous memory; unused free space is shown at the bottom of this page.
  • Page 29: On Screen Display

    On Screen Display. In Advanced mode all functions are available, Basic mode is more safety (for example network settings can’t be changed). In addition some settings done by On Screen Display can be enabled or disabled. © CUE, a.s. | All Rights Reserved.
  • Page 30: Factory Default

    This will remove all data, including Applications and File storage files. Configuration will be cleared, including IP address, password, and touch-screen calibration values. DHCP will be enabled and IP address will be get from DHCP server. © CUE, a.s. | All Rights Reserved.
  • Page 31 Backup command before the Restore command. • To see the backed-up/restored applications, click the Applications menu. To see backed-up/restored files and folders, click the File Storage menu. © CUE, a.s. | All Rights Reserved.
  • Page 32 Wired Touch Panels - User Manual Reset To restart your CUEunit, click the Reset button. License This page describes software license. © CUE, a.s. | All Rights Reserved.
  • Page 33 POSSESSION REGARDING THE SOFTWARE. License Grant: CUE grants to You, as an individual, a license to install and use one (1) copy of the Software on a single computer at a time; provided, however, that You may make copies of the Software solely for Your development of applications for CUE hardware and demonstration versions of such applications.