Starting Technique; Break-In Period - Lincoln Electric AIR VANTAGE 500 (AU) Operator's Manual

Table of Contents

Advertisement

B-7
Unlike other VRDʼs Lincoln uses micro processor con-
trol to monitor and establish the arc without the stick-
ing and shorting of the electrode to the job as seen in
many other VRD installations. Due to the requirement
of the resistance in the circuit to be low, for a VRD to
operate, a good metal-to-metal contact must be made
between the metal core of the electrode and the job.
Any damaged connection anywhere in the output cir-
cuit may limit the operation of the VRD. This includes
a good connection of the work return clamp and the
job. The work return clamp should be connected close
as practical to where the welding will be performed.
Some electrodes form a cone at the end of the elec-
trode after the welding arc has been broken, particu-
larly iron powder and low hydrogen electrodes.
This cone will need to be broken off in order to have
the metal core of the electrode to make contact.

STARTING TECHNIQUE

The starting technique that has successfully overcome
the problem is the push, twist, and peel technique.
This technique requires the operator to push the elec-
trode into the joint and twist.
The Push and Twist breaks off the cone and allows
the metal electrode to make contact.
The peel and lift of the electrode establishes a con-
trolled start to the welding arc. Normal welding tech-
nique for the application is then used.

BREAK-IN PERIOD

The engine used to supply power for your welder is a
heavy duty, industrial engine. It is designed and built
for rugged use. It is very normal for any engine to use
small quantities of oil until the break-in is accom-
plished. Check the oil level twice a day during the
break-in period. In general this takes 50 to 100 hours
of operation.
IMPORTANT
IN ORDER TO ACCOMPLISH THIS BREAK-IN, THE
UNIT SHOULD BE SUBJECTED TO HEAVY
LOADS, WITHIN THE RATING OF THE MACHINE.
AVOID LONG IDLE RUNNING PERIODS.
OPERATION
TYPICAL FUEL CONSUMPTION
Refer to Table B.1 for typical fuel consumption of the
AIR VANTAGE® 500 (AU) Engine for various operat-
ing settings.
Cummins B3.3 Engine Fuel Consumption
Low Idle -
no load 1425 RPM
High Idle -
no load 1900 RPM
DC CC Weld
Output 500
Amps @ 40 Volts
Auxiliary Power
12,000 VA
Air Compressor
60 CFM @ 100 PSI
Air Compressor
60 CFM @ 100 PSI
and DC, CC Weld
Output 500 Amps
@40 Volts
Air Compressor
60 CFM @ 100 PSI
and Auxiliary Power
12,000 VA
NOTE: This data is for reference only. Fuel consumption is
approximate and can be influenced by many factors, includ-
ing engine maintenance, environmental conditions and fuel
quality.
AIR VANTAGE® 500 (AU)
Table B.1
Cummins B3.3
Running Time for
56HP(42Kw)
25GAL.(94.6L)
@1800 RPM
(Hours)
.59 Gal./hour
42.4
(2.2 L/hour)
.87 Gal./hour
28.7
(3.3 L/hour)
2.10 Gal./hour
11.9
(7.9 L/hour)
1.44 Gal./hour
17.4
(5.5 L/hour)
1.29 Gal./hour
19.4
(4.9 L/hour)
2.46 Gal./hour
10.2
(9.3 L/hour)
1.94 Gal./hour
12.9
(7.3 L/hour)
B-7