Adjustment Facilities On The Phono Module Mm; Setting The Input Sensitivity - T+A E 1000 Series User Manual

Phono module
Table of Contents

Advertisement

Available languages

Available languages

Adjustment facilities on the Phono module MM

Switch positions
Setting the input
sensitivity
(Gain)
Input sensitivity
1L
2L
Miniature switches „1" are used to set the desired input sensitivity for the
left (1L) and right (1R) channels as shown in Table 1.
The information you need for this will be included in the manufacturer's
specification for the pick-up system you intend to use. Select the value
which is closest to the manufacturer's stated figure. It is essential to set
the same value for both channels.
If you do not have access to the manufacturer's specification, a good
starting point for sensitivity is 3.5 mV. This is the factory default setting.
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
ON
OFF
OFF
18
1R
2R
OFF
ON
OFF
OFF
OFF
Input sensitivity [mV]
...
6,0
10,0
...
3,5
6,0
...
2,5
3,5
...
1,5
2,5
...
1,0
1,5
Table 1

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

Pa 1100 ePhe mmPhe mc

Table of Contents