OPERATING INSTRUCTIONS & PARTS MANUAL
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOUR-
SELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH
INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!
DESCRIPTION
®
The Air King
20" (50.8 cm) I-Beam mount fan features 3-speed pull cord
operation and a 3-paddle fan blade. This fan has a permanently lubricated
motor with a 9 ft. (2.74 m) 18/3 cord set and is constructed of sturdy,
powder coated steel.
SPECIFICATIONS
Motor ...................................... 120 V, 50/60 Hz
Blade diameter ........................ 20" (50.8 cm) Model 9520
Speeds .................................... 3
Control ..................................... Pull Cord
Air flow distribution .................. 360°
Approvals................................. UL/ETL Listed. Close mesh fan guard
MODEL
SPEED
HIGH
CFM
7510
M
3
/s
3.54
RPM
1560
Amps
1.78
Watts
207
dB A
62
GENERAL SAFETY INFORMATION
1. Make certain that the power source conforms to the electrical
requirements of the fan.
2. The power cord is equipped with a three-prong grounded plug that
must be inserted into a matching receptacle. Under no circumstances
should the grounding prong be cut off the plug. Where a two-prong wall
receptacle is encountered, it must be replaced with a properly grounded
three-prong receptacle installed in accordance with the National Electrical
Code (NEC) and all applicable local codes and ordinances. This work
must be done only by a qualified electrician, using copper wire only.
WARNING: USE OF A THREE-PRONG TO TWO-PRONG ADAPTER IS
NOT RECOMMENDED. IMPROPER CONNECTION MAY CREATE THE
RISK OF ELECTRICAL SHOCK. USE OF SUCH ADAPTERS IS NOT
PERMITTED IN CANADA.
3. Where possible, avoid the use of extension cords. If they must be used,
minimize the risk of overheating by ensuring that they are UL listed and
of the proper gauge and length. Never use a single extension cord to
operate more than one fan.
4. Do not insert fingers or foreign objects into the fan. Do not block or
tamper with the fan in any manner while it is in operation. Do not touch
the fan while in operation or just after it has been turned off, as some
parts may be hot enough to cause injury.
5. Unplug power cord before installing or servicing the fan.
WARNING: DO NOT DEPEND UPON THE ON-OFF SWITCH AS THE
SOLE MEANS OF DISCONNECTING POWER WHEN INSTALLING OR
SERVICING THE FAN. ALWAYS UNPLUG THE POWER CORD.
6. This fan is intended for general use ONLY. It must NOT be used in
potentially dangerous locations such as flammable, explosive, chemical
laden or wet atmospheres.
7. DO NOT mount fan near windows or bay doors. Rain may create an
electrical hazard.
8. Completely reassemble fan, according to instructions before
reconnecting to power supply.
WARNING:
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE
THIS FAN WITH ANY SOLID STATE SPEED CONTROL DEVICE.
WARNING:
THIS PLUG IS A SAFETY FEATURE, TO REDUCE THE RISK OF
FIRE, ELECTRIC SHOCK AND PERSONAL INJURY. DO NOT REMOVE, REPLACE,
REPAIR ORTAMPERWITHTHE ORIGINALLY SUPPLIED PLUG. IFTHE FAN DOES
NOT FUNCTION PROPERLY, IT MAY BE DUE TO THE SAFETY DEVICE INCOR-
PORATED IN THIS PLUG. RETURN TO AN AUTHORIZED SERVICE CENTER
OR CALL 800-233-0268, MONDAY - FRIDAY, BETWEEN 8:00 A.M. AND 5:00
P.M. EST. IF THE PLUG WARNING LABEL IS MISSING OR DAMAGED, CALL
THE TOLL FREE NUMBER FOR A REPLACEMENT LABEL.
Rev. A 9/07
READ AND SAVE THESE INSTRUCTIONS
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
meets OSHA
requirements.....................
9520
MED
LOW
5010
3735
2.36
1.76
1041
776
1.46
1.02
167
115
55
48
20" I-BEAM MOUNT FAN
20" (50.8 cm) MODEL 9520
9. This Fan is not suitable for use in hazardous locations. Please refer to
National Electric Code (NEC) Article 500 or applicable state or local
codes or standards relating to electrical requirements for Hazardous
locations. THIS FAN DOES NOT MEET THE REQUIRMENTS OF
NEC ARTICLE 500 (2002).
:
WARNING
This fan should be used only in a clean, dry
environment. Mounting of this product in any way other then
specified in the instruction sheet will null and void the
manufacturer's warranty
WARNING: BECAUSE OF SIZE AND WEIGHT OF THIS FAN, MAKE
SURE ALL PARTS ARE COMPLETELY ASSEMBLED ACCORDINGTO
INSTRUCTIONS.FAILURETO DO SO COULD RESULT IN FAN COMING
APART DURING OPERATION AND/OR PERSONAL INJURY.
I-BEAM MOUNT INSTALLATION
1. Locate the L-shaped pipe to the desired location on the I-Beam flange.
Install the 5/16 x 2" U-Bolt over the pipe and through the clamping plate
holes. The flat part of the clamping plate fits on the I-Beam flange and
the end with the slight bend goes against the pipe. Install flat washer,
lock washer and nuts. Finger tighten the nuts on the U-Bolt. (Figure 1)
2. Slide the clamping plate onto I-Beam flange until U-Bolts contact
flange.
3. Adjust L-shaped pipe so forward clamp plate is as close to the label
at the bend as possible.
4. Tighten nuts on bolt so pipe does not move.
5. Screw on the adapter mount as far as it will go on to the L-shaped
pipe. Tighten set screw in pipe coupling with provided allen key.
6. Align Yoke with grill mounting threads. Loosely attach one Grill Knob
and one Rubber Spacer to the Head Assembly. Attach the other Grill
Knob and Rubber Spacer to the Head Assembly and FIRMLY tighten.
Return to the first Grill Knob and FIRMLY tighten. (Figure 2)
Tighten Clamp
Plate Here
Fan Head
Figure 1
1
Commerical Style Fan
.
U-Bolts
1/4" Set Screw
Yoke
5/16 Nut
5/16 Lock
Washer
5/16 Flat
Washer
Tighten
Bolt
5084037
Need help?
Do you have a question about the 9520 and is the answer not in the manual?
Questions and answers