Safety And Usage Information; Introduction - IMR EX660 User Manual

Personal multi-gas detector
Hide thumbs Also See for EX660:
Table of Contents

Advertisement

IMR EX660 Manual
1. S
U
AFETY AND
Improper use or usage in an inappropriate environment may degrade the instruments performance.
Read the safety information below before using/operating this device.
 Do not use a damaged device. Check for cracked or missing parts before use.
 Before use it is advised that a "Bump Test" be performed. See section 6.3 for more information.
If the reading is out of range then the device should be calibrated. See section 6.7 and 6.8.
 Periodic "Bump Tests" will allow for testing of the sensor response, visual, audible and vibrate
functions.
 Do not use accessories that are not designed to be used with the EX660.
 Only use the charger provided with the EX660. Do not charge the device in hazardous
environments.
 Do not expose the device to high gas concentrations for an extended period. Doing so can harm
sensor performance and possibly damage them.
 Do not use the device in environments that contain lead compounds, sulfate compounds, organic
phosphorus compounds, or silicon. These compounds can damage the sensor cells.
 Avoid exposure to environments that contain H2S, Hydrocarbons or acidic gases for an extended
period. If the device has been used in these environments preform a "Bump Test" before its next
use. See section 6.3.
 Avoid exposure to environments with the potential for electric shock, strong magnetic fields or
extreme continuous mechanical vibration.
 Do not discard the lithium battery in the trash. Follow local regulatory requirements for disposal
of the battery.
 Do no preform any unauthorized maintenance of the device.
 Avoid dropping the device from heights and extreme impacts.
 For usage information not included in this manual contact IMR.
2. I
NTRODUCTION
The EX660 is a compact and lightweight multi-gas detector that continuously measures combustibles
such as O2, CO, H2S and other toxic gases in ambient air. It can be equipped with up to 6 different
sensors. It has a rugged and watertight design (IP66). With an impact resistant rubberized case to
meet the toughest requirements of the harshest environments.
3634 Central Ave. St. Petersburg, FL 33711
www.imrusa.com
info@imrusa.com
Environmental Equipment, Inc.
I
SAGE
NFORMATION
THE PRIDE OF THE COMPANY – MADE IN THE USA
IMR EX660
Phone: 727-328-2818 / 800-RING-IMR
Fax: 727-328-2826
Page 3 of 14