1. General Information
These instructions should be read carefully and retained for further
reference and maintenance.
Timeguard reserve the right to alter these instructions at any time.
Note:
Up to date instructions will always be available for download at
www.timeguard.com/pdf-instructions
2. Safety
• Before installation or maintenance, ensure the mains supply to the
luminaire is switched off and the circuit supply fuses are removed or the
circuit breaker turned off.
• It is recommended that a qualified electrician is consulted or used for the
installation of this luminaire and install in accordance with the current
IEE wiring and Building Regulations.
1
• Check that the total load on the circuit including when this luminaire is
fitted does not exceed the rating of the circuit cable, fuse or circuit
breaker.
• To clean use a clean dry cloth only. Do not use liquid cleaners.
3. Technical Specifications
• Mains Supply:
• This luminaire is of class I construction and must be earthed
• IP Rating:
• Operating Temperature:
• Standby Power:
• PIR Detection Range:
• Detection Angle:
• PIR Sensitivity Adjustment:
230V AC 50Hz
IP65
0˚ to 40˚C
<0.5W
6m at a 3m mounting
height
100˚ (Fixed)
Yes: (Detection distance)
0.5m to 6m