5 Detecting and rectifying faults

4.14

Switching off the product's functions

4.14.1 Switching off hot water generation
Applicability: Product with hot water generation through external domestic
hot water cylinder
1.
To switch off cylinder charging without switching off
heating mode, press
The set hot water temperature flashes in the display.
2.
Use the
button to set the hot water temperature to
Cylinder charging off.
3.
Confirm by pressing
Cylinder charging is switched off.
Only the frost protection function for the cylinder
remains active.
4.14.2 Switching off heating mode (Summer
mode)
1.
To switch off heating mode without switching off hot
water generation, press
The value of the heating flow temperature appears
in the display.
2.
Use the
button to set the heating flow temperature to
Heating off.
3.
Confirm by pressing
Heating mode is switched off
The
symbol appears in the display.
4.15
Protecting the heating installation against
frost
4.15.1 Frost protection function
Caution.
Risk of material damage due to frost.
The frost protection function cannot guaran-
tee flow through the entire heating installa-
tion, which means that parts of the heating
installation may freeze and therefore become
damaged.
During a period of frost, ensure that the
heating installation remains in operation
and that all rooms are sufficiently heated,
even when you are away.
Note
To keep the frost protection devices active, you
should switch your product on and off using the
controller, if one is provided.
If the heating flow temperature falls below 5 °C when the
on/off button is on, the product comes into operation and
heats the circulating water to approx. 30 °C on both the heat-
ing side and the hot water side (if available).
10
(
).
.
( ).
.
4.15.2 Draining the heating installation
Another way to protect the heating installation and the
product from frost for very long switch-off times is to drain
them completely.
Consult a competent person about this.
5
Detecting and rectifying faults
If faults occur, proceed in accordance with the table in
the appendix.
Troubleshooting (→ Page 12)
If you are unable to eliminate the faults using the spe-
cified measures, if fault messages (F.xx) are displayed,
or if the product does not function correctly, contact a
competent person.
6
Calling up (Live monitor) status
codes
1.
Press
and
at the same time.
The menu is called up.
Navigate to Menu → Live monitor and confirm by
2.
pressing
.
Status codes – Overview (→ Page 13)
7

Care and maintenance

7.1

Maintenance

An annual inspection of the product carried out by a compet-
ent person is a prerequisite for ensuring that the product is
permanently ready and safe for operation, reliable, and has a
long working life.
7.2

Caring for the product

Caution.
Risk of material damage caused by un-
suitable cleaning agents.
Do not use sprays, scouring agents, de-
tergents, solvents or cleaning agents that
contain chlorine.
Clean the casing with a damp cloth and a little solvent-
free soap.
Operating instructions ecoTEC exclusive 0020193967_00