4 Operation
4.14

Setting the target cylinder temperature

Applicability: Product with integrated hot water generation and shift-load
cylinder
Conditions: Water hardness: > 3.57 mol/m³
Have a competent person take appropriate measures to
protect against Legionella.
Set the target cylinder temperature to a maximum of 50
°C.
4.15

Switching off the product's functions

4.15.1 Switching off heating mode (Summer
mode)
1.
To switch off heating mode without switching off hot
water generation, press
The value of the heating flow temperature appears
in the display.
2.
Use the
button to set the heating flow temperature to
Heating off.
3.
Confirm by pressing
Heating mode is switched off.
The
symbol appears on the display.
4.15.2 Switching off hot water generation
Applicability: Product with hot water generation through external domestic
hot water cylinder
1.
To switch off cylinder charging without switching off
heating mode, press
The set hot water temperature flashes in the display.
2.
Use the
button to set the hot water temperature to
Heating off.
3.
Confirm by pressing
Cylinder charging is switched off.
Only the frost protection function for the cylinder
remains active.
10
( ).
.
(
).
.
4.16
Guaranteeing the correct filling pressure of
the heating system
4.16.1 Checking the filling pressure of the heating
installation
Note
To ensure that the heating installation operates
smoothly, the filling pressure when the heating
installation is cold must be between 0.1 MPa and
0.2 MPa (1.0 bar and 2.0 bar) or lie between the
two dashed lines in the bar graph display.
If the heating installation extends over several
storeys, a higher filling pressure may be required
for the heating installation. Ask a competent per-
son for details.
In addition, the
one minute.
If the filling pressure in the heating installation
falls below 0.05 MPa (0.5 bar), then the product
switches off. The display alternates between the
fault message F.22 and the current filling pres-
sure.
1.
Press
twice.
The values for the current filling pressure and for the
minimum and maximum filling pressures appear in
the display.
2.
Check the filling pressure in the display.
1 / 2
System pressure: 0.1 ... 0.2 MPa (1.0 ... 2.0 bar)
The filling pressure is in the intended pressure range.
2 / 2
Filling pressure: < 0.08 MPa (< 0.80 bar)
Fill the heating installation. (→ Page 10)
If you have topped up the installation with suf-
ficient heating water, the display automatically
disappears after 20 seconds.
4.16.2 Filling the heating installation
Caution.
Risk of material damage due to heating
water that is extremely calciferous or cor-
rosive or contaminated by chemicals.
Unsuitable tap water damages the seals
and diaphragms, blocks components in the
product and heating installation through
which the water flows and causes noise.
Only fill the heating installation with suit-
able heating water.
1.
Ask a competent person where the filling cock is loc-
ated.
2.
Connect the filling tap to a heating water supply in the
way you were told by the competent person.
3.
Open all radiator valves (thermostatic radiator valves) of
the heating installation.
4.
Open the heating water supply.
Operating instructions ecoTEC plus 0020245033_00