Scientific PS3200 Series User Manual

Programmable switch mode power supplies

Advertisement

Programmable Switch
Mode Power Supplies
PS3200 Series
User Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PS3200 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Scientific PS3200 Series

  • Page 1 Programmable Switch Mode Power Supplies PS3200 Series User Manual...
  • Page 2 Information in this manual supercede all corresponding previous released material. Scientific continues to improve products and reserves rights to amend part or all of the specifications, procedures, equipment at any time without notice. Scientific shall not be liable errors contained in this document or if for incidental or consequential damages in connection with the furnishing, performance or use of this material.
  • Page 3: Table Of Contents

    Thermal protection Cooling Output Connecting the load Local & remote Sensing Constant voltage and constant current mode 4.10 Hold up time 4.11 Over voltage protection 4.12 Under current limit 4.13 Fold back protection 4.14 AC fail User Manual PS3200 Series...
  • Page 4 Read measured output current 6.1.15 Fold back enable/disable 6.1.16 Read measured output power 6.1.17 Read measured internal temperature 6.1.18 Status Chapter 7 Maintenance Troubleshooting Chapter 8 Dispatch procedure for service & Warranty Dispatch procedure for service Warranty User Manual PS3200 Series...
  • Page 5 Models with Output Voltage 16V to 1000 V, 3200 W Power The PS3200 series power supplies is designed for compact 2 U size with user friendly operation and higher efficiency. This range offer multi ranging output characteristic which makes them more flexible than traditional or rectangular output characteristic power supplies as they give multiple voltage and current combination in a single power supply.
  • Page 6: Safety Instructions

    , causing hazardous conditions. Environmental conditions Please do not operate the instrument in the place that vibrates, dusty, under direct sunlight or where there is corrosive air. The Scientific Power supplies are designed for safety, applies to following conditions. - Indoor use.
  • Page 7: Safety Symbols

    Follow the instructions for proper procedures. Symbols marked on instruments Attention refer to the manual. Hazardous voltage exists, Caution ! Electric shock. Indicates Protective Ground Terminal Indicates Ground Terminal Off ( Supply ) On ( Supply ) User Manual PS3200 Series...
  • Page 8: Chapter 1 Technical Specifications

    0-100.0 0-40.00 0-53.33 0-40.00 0-32.00 Resolution Voltage 10 mV 10 mV 10 mV 10 mV 10 mV 10 mV 100 mV Current 100 mA 100 mA 100 mA 10 mA 10 mA 10 mA 10 mA User Manual PS3200 Series...
  • Page 9 0-600.0 0-800.0 0-1000 Current (A) 0-26.66 0-20.00 0-10.66 0-5.33 0-4.00 0-3.20 Resolution Voltage 100 mV 100 mV 100 mV 100 mV 100 mV Current 10 mA 10 mA 10 mA 10 mA 10 mA 10 mA User Manual PS3200 Series...
  • Page 10 Internal Fuse L : 20 A, 6.3 x 32 mm ceramic fuse. Power Factor 0.99 @ full load / 0.98 @ 50% load Turn On delay 600 ms after mains switched ON Inrush current <50A Hold up Time 20 ms User Manual PS3200 Series...
  • Page 11 2. Sensing at the rear panel of the power supply unit at sense terminals. 3. Unit warm up time is 30 min. 4. Minimum output voltage guaranteed to maximum of 0.2% rated. 5. Minimum output current guaranteed to maximum of 0.4% rated. User Manual PS3200 Series...
  • Page 12 Rear panel when unit is used on table top : 432.0 mm Side view when unit is used on table top : 25.0 mm 27.0 mm 557 mm User Manual PS3200 Series...
  • Page 13 Top view : 432.0 mm Output bus dimension : 27.0 in mm User Manual PS3200 Series...
  • Page 14: Chapter 2 Panel Controls

    8 CV LED indicator : LED indicator for CV , lights when power supply is in constant voltage mode. 9 Set & Comm : Push button control for selecting setting for voltage or current. When pressed in combination with “Fn” button, “Comm” mode selected. Comm mode used for User Manual PS3200 Series...
  • Page 15 17 Instrument handel : Mounted on either side of the power supply unit for lifting the unit while mounting in 19” rack cabinet. 18 Mounting holes : Mounting holes used in fixing the unit in 19” rack cabinet. User Manual PS3200 Series...
  • Page 16 USB “B” connector , to connect the power supply to computer for remote control operations. 8 & 9 J1- J2 RJ45 connector , gives connections for RS232 & RS485 operations. 10 RJ45 connector Ethernet / LAN ( Optional) User Manual PS3200 Series...
  • Page 17 Connector J2 ( RJ45 ) Master - Slave Pin 1 Return ground Pin 2 Slave Connect Pin 3 Tx + Pin 4 Rx + Pin 5 Rx – Pin 6 Tx – Pin 7 Not Connected Pin 8 Not Connected User Manual PS3200 Series...
  • Page 18 Pin 19 AC Fail status output Pin 20 DC Fail status output Pin 21 Remote Control status output Pin 22 Ground Analog Programming Pin 23 Ground Analog Programming Pin 24 Current Monitoring Output Pin 25 Not connected User Manual PS3200 Series...
  • Page 19 This is cable is end User specific depends on the connections to remote units, panels etc. One end of this cable is RJ45 (male) and other end is DB 9 ( Female) connector. User can assemble it as per their required length, not more than 9 meter. Also available as optional accessories from Scientific. DB 9 (F) 9 Pin Connector...
  • Page 20: Chapter 3 Installation

    If damage is detected, file a claim with carrier immediately and inform the Dealer ,sales or authorized service facility nearest to you or Scientific. If the contents in the container do not conform to the packing list, notify us or your dealer. Before putting this instrument in operation, make sure you go through the manual, safety and Cautions guidelines.
  • Page 21 Else order the Rear Panel Support Plates optional available. Caution ! Ensure that the supplied screws used for mounting only, else use appropriate screws of size M3x 6 mm. Ensure that they do not penetrate more than 6 mm inside. User Manual PS3200 Series...
  • Page 22 Connect the cables on bus bar, push the protection cover to touch the rear panel and fix with the screws. Before any making electrical connections or removing the connections, ensure the power supply bus is fully discharged. Please refer to safety instructions, before connecting / disconnecting the output connections. User Manual PS3200 Series...
  • Page 23 Switch the POWER switch to Off position. 3.6.3 DC output check Connect the DVM/DMM in appropriate voltage range depending on power supply output voltage. Press the push button “Output”, the associated output LED will light, indicating the output is available User Manual PS3200 Series...
  • Page 24 These two simple tests , ensure that the power supply is largely working and further can be checked and tested for the other modes and features after going through manual. In Description chapter , all the features and modes are explained in details. Request to go through each for better understanding and use. User Manual PS3200 Series...
  • Page 25: Chapter 4 Descriptions

    There is no external fuse in the unit, a safety fuse is installed inside the unit. In event of fuse blown, the fuse must be replaced only by Scientific authorised service personal. When power supply unit is switched ON, its inrush current is limited by internal circuitry. Switching ON and OFF at faster rate, may result in over heating of current limiter, resulting higher inrush current.
  • Page 26: Cooling

    70 mm 20 Nm PS32-100, PS40-80 35 mm 20 Nm PS60-52, PS80-40, PS100-32, 10 mm 20 Nm PS160-20, PS120-26, PS160-20, 4 mm 20 Nm PS300-10, PS600-5, 2.5 mm 20 Nm PS800-4, PS1000-3 1.5 mm 20 Nm User Manual PS3200 Series...
  • Page 27: Local & Remote Sensing

    Such as grounded positive power supply where the negative output terminal is connected to protective earth potential, similarly negative power supply where the positive output terminal is connected to protective earth potential. User Manual PS3200 Series...
  • Page 28: Constant Voltage And Constant Current Mode

    “Fn” button. When the function is enabled Fold LED will light. When the load current FOLd crosses set CV or CC value, the output will be switched OFF. The display will show “ ” Once the output is switched OFF, it can be reset, by pressing Output push button. User Manual PS3200 Series...
  • Page 29: Ac Fail

    DIP switch. Note that, the Analog connector input signals for remote control, have reference to – ve output terminals and they are not floated. Wrong connection can cause earth loops, may cause faults. Care User Manual PS3200 Series...
  • Page 30 Vset is voltage to be fed to pin 9 ; Vout is required output voltage ; Vrated is the rated output voltage of power supply unit , V rated is 100V , and we wish to set output to 50V, then Vset will be (5x50)/100 = 2.50 V User Manual PS3200 Series...
  • Page 31 In remote programming, the output of power supply can be remotely switched OFF by applying TTL ( 5 V) at pin 15 of analog connector , with reference to ground at Pin 2. The power supply remain switched OFF, until the TTL voltage is goes 0V. User Manual PS3200 Series...
  • Page 32 To enable the output to previous state (before the power switch as OFF) move switch 4 to up. To disable the output or to keep the output OFF on mains AC switch ON, keep the switch 4 to down. User Manual PS3200 Series...
  • Page 33 – Connecting single loads Load The load can be connected in either in local sense or in remote sense mode. In case of local sense mode the sense points are at User Manual PS3200 Series...
  • Page 34 , which will Diode damage the power supply, to avoid, a bypass diode is connected in parallel to output terminal of power supply. The diode should be of higher rating and should have high heat dissipating capability. User Manual PS3200 Series...
  • Page 35 5.2 Voltage & Current setting : To set the desired voltage or current, press “set” push button, the set LED will light and the display will show previous voltage current set values. To set the new value of voltage, rotate Voltage encoder until the desired value. Similarly to set the new value User Manual PS3200 Series...
  • Page 36 You can change the encoder resolution in coarse, medium or fine by pressing voltage encoder switch. The maximum under voltage can be set to approx. 95 % the set voltage. The minimum under voltage value can be set to 0 V. User Manual PS3200 Series...
  • Page 37 By varying current encoder mode, Fold function in CV or CC mode is selected. To switch off the Fold, select “Off” . Similarly, desired delay time can be set for Fold function, by varying voltage encoder, select “F-dL”. (last value) (last value) User Manual PS3200 Series...
  • Page 38 You can also access “Set”, “OV” , “UV” and “Fold” menu in output ON state. 5.7 Communication set menu The communication menu is selected by pressing the “ Fn” push button, followed by “COMM” push button. This menu is active only in output OFF condition and Local mode. User Manual PS3200 Series...
  • Page 39 By varying current encoder baud parameters can be changed to 4800, 9600 and 19.2k, when baud is selected. By varying current encoder address can be changed when Address is selected. The address range is 1 to User Manual PS3200 Series...
  • Page 40 To unlock the front panel , press push button “Fn” and then press “UV” in sequence, the display will show in left window and in right window. the panel will be unlocked. User Manual PS3200 Series...
  • Page 41 This command used to identify the unit connected on remote, returns the Instrument Model number. Syntax: *IDN? Power supply return: PS100-16 POWER SUPPLY Examples shown above is in case of PS100-16. Return reply indicates instrument model PS100-16 is connected. User Manual PS3200 Series...
  • Page 42 The display returns to its previous position. 6.1.8 Set output On / OFF This command is used to ON/OFF the output of power supply To switch ON the output ; Syntax: OUTP 1 Power supply returns : OP ON User Manual PS3200 Series...
  • Page 43 10.0000, this means the over voltage protection is set to 10.0000 V. 6.1.13 Read measured output voltage This command returns the measured output voltage of power supply. Syntax: VOLT? Power supply returns : xx.xxxx for example 10.0000 is measured output voltage. User Manual PS3200 Series...
  • Page 44 0XXX Status Register bit 7 ....bit 0 Status Fault Interlock Status PS OK Status ACF Status OTP (Over temperature ) OVP (Over Voltage) FOLD Status OP ( Output ON/OFF) Status CV-CC Status CC=1 CV=0 User Manual PS3200 Series...
  • Page 45 In such case we recommend to send the power supply unit to Scientific for service and repairs. In case of power supply failure, when it needs service / repairs , there is no User repairs or replaceable parts inside the power supply unit.
  • Page 46 There is no user replaceable fuse in the power supply. Only inside power supply unit there are fuses to protect the fault conditions. In case of these gets open, only Scientific qualified or authorized trained personal should replace the fuse.
  • Page 47 Service Center or factory. 8.2 Warranty conditions Scientific warrants all its Instruments to be free from defects in material and workmanship when used under normal operating conditions in accordance with the instructions given in the manual for a period of 12 (Twelve) months from date of purchase from Scientific or its authorized dealers.

Table of Contents