Troubleshooting Guide - Craftsman 919.16724 Operator's Manual

Permanently lubricated tank mounted air compressor
Table of Contents

Advertisement

Available languages

Available languages

Performing repairs may expose voltage sources, moving parts or compressed air sources,
moving parts or compressed air sources. Personal injury may occur. Prior to attempting any
repairs, unplug the air compressor and bleed off all air tank air pressure.
PROBLEM
Excessive tank pressure - safety
valve pops off.
Air leaks at fittings.
Air leaks in air tank or at air tank
welds.
Air leaks between head and valve
plate.
Pressure reading on the regulated
pressure gauge drops when an
accessory is used.
Air leak from safety valve.
TROUBLESHOOTING
CAUSE
Pressure switch does not shut off
motor when compressor reaches
"cut-out" pressure.
Pressure switch "cut-out" too
high.
Tube fittings are not tight enough.
Defective air tank.
Leaking seal.
It is normal for "some" pressure
drop to occur.
Possible defect in safety valve.
15-Eng
CORRECTION
Move On/Auto/Off lever to the
"OFF" position, if the outfit does
not shut off contact a Trained
Service Technician.
Contact a Trained Service
Technician.
Tighten fittings where air can be
heard escaping. Check fittings
with soapy water solution. DO
NOT OVERTIGHTEN.
Air tank must be replaced. Do not
repair the leak.
Do not drill into, weld or otherwise
modify air tank or it will weaken.
The tank can rupture or explode.
Contact a Trained Service
Technician.
If there is an excessive amount of
pressure drop when the accessory
is used, adjust the regulator follow-
ing the instructions on page 6.
NOTE: Adjust the regulated pres-
sure under flow conditions (while
accessory is being used).
Operate safety valve manually by
pulling on ring. If valve still leaks,
it should be replaced.
D21996

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

919.167240

Table of Contents