Troubleshooting Guide - Craftsman 921.152150 Owner's Manual

4-gallon ¾ hp oil-free, belt drive universal motor and pump
Hide thumbs Also See for 921.152150:
Table of Contents

Advertisement

Available languages

Available languages

Troubleshooting Guide

The air compressor should be turned off and unplugged from the power source before any maintenance
WARNING
is performed as well as the air bled from the tank and the unit allowed time to cool. Personal injuries
could occur from moving parts, electrical sources, compressed air, or hot surfaces.
PROBLEM
Air leaks at the check valve or at the pres-
sure relief valve.
Air leaks between head and cylinder.
Air leak from safety valve.
Pressure reading on the egulated pressure
gauge drops when an accessory is used.
Excessive tank pressure.
Motor will not start.
Excessive moisture in the discharge air.
Air leaks from the tank body or tank welds.
POSSIBLE CORRECTION
A defective check valve results in a constant air leak at the pressure relief
valve when there is pressure in the tank and the compressor is shut off.
Drain the tank, then remove and clean or replace the check valve.
Be sure of proper torque on head bolts. If leak remains, contact a service
technician.
Operate the safety valve manually by pulling on the ring. If the valve con-
tinues to leak when in the closed position, it should be replaced.
If there is an excessive amount of pressure drop when the accessory is
used, replace the regulator.
NOTE
Adjust the regulated pressure under flow conditions (while accessory is
being used). It is normal for the gauge to show minimal pressure loss dur-
ing initial use of the tool.
Move the Auto-On/Off lever to the Off position. If the unit doesn't shut off,
unplug it from the power source and contact a service technician.
Make sure power cord is plugged in and the switch is on. Inspect for the
proper size fuse in your circuit box. If the fuse was tripped, reset it and
restart the unit. If repeated tripping occurs, replace the check valve or
contact a service technician.
Remove the water in the tank by draining after each use. High humidity
environments will cause excessive condensation. Utilize water filters on
your air line.
NOTE
Water condensation is not caused by compressor malfunction. Be sure
the compressor's air output is greater than your tool's air consumption
rate.
Never drill into, weld or otherwise modify the air tank or it will weaken. The
tank can rupture or explode. Compressor cannot be repaired. Discontinue
use of the air compressor.