  • Page 1 毅丰 2017.07.03 受控正本 MP-300Z User Manual Please read the instructions carefully before use...
  • Page 2: Table Of Contents

    CONTENTS 1. Safety Instructions ....................2 2. Technical Specifications ..................4 3. How To Set The Unit ....................5 3.1 Control panel ....................5 3.2 Main Functions ....................6 4. How to Control the Unit ..................9 4.1 DMX Controller ....................9 4.2 DMX 512 Configurations .................
  • Page 3: Safety Instructions

    1. Safety Instructions Please read the instruction carefully which includes important information about the installation, usage and maintenance. WARNING  Please keep this User Guide for future consultation. If you sell the unit to another user, be sure that they also receive this instruction booklet. ...
  • Page 4 Please contact the nearest authorized technical assistance center. Always use the same type spare parts.  DO NOT touch any wire during operation as high voltage might be causing electric shock. For 230V 50Hz power supply, maximum fixtures that can be connected together from the same outlet is 8pcs; For 120V 60Hz power supply, maximum fixtures that can be connected together from the same outlet is 4pcs Warning: ...
  • Page 5: Technical Specifications

    2. Technical Specifications ◇ DMX 512 Channels: 5/6/8 channels ◇ Two Operation Modes: DMX, Master/Slave ◇ Strong die-casting aluminum housing ◇ Perfect strobe with smooth dimming 0~100% ◇ Outstanding color macro effect ◇ Flexible hanging/standing dual brackets for easy mounting Power Voltage: AC 100~240V, 50/60Hz ...
  • Page 6: How To Set The Unit

    3. How To Set The Unit 3.1 Control panel 1. DMX IN: For DMX512 link, use 3-pin XLR plug cable to input DMX512 single. 2. DMX OUT: For DMX512 link, use 3-pin XLR plug cable to output DMX512 single to the next unit. 3.
  • Page 7: Main Functions

    3.2 Main Functions To select any of the given functions, press the MENU button up to when the required one is showing on the display. Select the function by the ENTER button and the display will blink. Use the DOWN and UP button to change the mode. Once the required mode has been selected, press the ENTER button to setup, to go back to the functions without any change press the MENU button again.
  • Page 8 DMX Address Select the DMX Address, press the ENTER button and the display will blink. Use the DOWN and UP button to change the DMX 512 Address, and then press the ENTER button to save. Back to the previous functions without any change press the MENU button. Channel Mode Select the Channel Mode, press the ENTER button and the display will blink.
  • Page 9 Black Out Select the Black Out, press the ENTER button and the display will blink. Use the DOWN and UP button to select the Yes (blackout) or Hold (keep the present status). Once selected, press the ENTER button to save or automatically exit menu mode without any change. Back to the previous functions without any change press the MENU button.
  • Page 10: How To Control The Unit

    Temp. Select the Temp. , press the ENTER button and the display will show the current running temperature of the fixture. Press the MENU button to exit. Fixture Time Select the Fixture Time, press the ENTER button and the display will show the running time of the fixture.
  • Page 11: Dmx 512 Configurations

    press the MENU button again. If you use please refer to the following diagram to address your DMX512 channel for the first 4 fixtures. Fixture 1 Fixture 2 Fixture 3 Fixture 4 Channel Mode Address Address Address Address 5 channels 6 channels 8 channels 4.2 DMX 512 Configurations...
  • Page 13: Dmx 512 Connections

    5. DMX 512 Connections The DMX512 is widely used in intelligent lighting control, with a maximum of 512 channels. 1. If you using a controller with 5 pins DMX output, you need to use a 5 to 3 pin adapter-cable. 2.
  • Page 14: Troubleshooting

    7. 3 pin XLR connectors are more popular than 5 pin XLR. 3 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+) 5 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+), Pin 4/Pin 5: Not used.
  • Page 15: Fixture Cleaning

    7. Fixture Cleaning The cleaning must be carried out periodically to optimize light output. Cleaning frequency depends on the environment in which the fixture operates: damp, smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit’s optics. ...
  • Page 16 Declaration of Conformity We declare that our products (lighting equipments) comply with the following specification and bears CE mark in accordance with the provision of the Electromagnetic Compatibility (EMC) Directive 89/336/EEC. EN55103-1: 2009 ; EN55103-2: 2009; EN62471: 2008; EN61000-3-2: 2006 + A1:2009 + A2:2009; EN61000-3-3: 2008. &...