CARING FOR YOUR FURNACE
WARNING: Danger of bodily injury or death. If equipped
with accessory blower, turn off the electric power supply at the
disconnect switch, fuse box or service panel before removing
any access doors or service panels from unit.
BLOWER ACCESSORY 2302 & 2303
This accessory can be operated using the factory equipped
three-prong (grounding) plug and cord or may be field wired. See
field wiring installation instructions below. When using the plug
and cord, for your protection against shock hazard, it must be
plugged directly into a properly grounded three prong receptacle.
DO NOT REMOVE THE PRONG. All electrical work must
conform to your local codes and ordinances, or in their absence,
with National Electrical Code ANSI/NFPA 70. In Canada,
Canadian Electrical Code C22.1. It must also be electrically
grounded. If you are not familiar with wiring codes in general,
have a competent electrician do the job.
WARNING: Danger of property damage bodily injury
or death. Unplug the service cord from the electrical outlet
before removing or working on this blower kit.
MOUNTING - MODEL 2302
1.
Remove the knock-out plates "A" and "B" from right
side of the furnace. Figure 1 page 19
2.
Remove the junction box cover and place the blower
and junction box in position as shown on
Figure 1 page 19.
3.
Attach the blower and the junction box to the inner
casing using the pre-punched holes with screws "C"
and "D" provided with this kit. See Figure 1 on page 19
for proper mounting hole to use with your furnace
model (see rating plate for furnace model number).
Reattach the junction box cover.
18
FIGURE 17
4.
After the blower and junction box are installed, rotate
bushing "H" if needed to prevent the motor wire from
binding against the blower casing.
5.
Plug in the factory supplied three-prong (grounding)
plug and cord or see field wiring instructions below.
MOUNTING - MODEL 2303
1.
Set the blower on top of the furnace with the rear
flange of the blower cabinet behind the furnace
cabinet. This will place the back of the blower cabinet
against the wall surface. See Figure 2 page 19
2.
Plug in the service cord.