4-2. TEST RUNNING WITHOUT WATER

Number of times the
START/PAUSE
button is pressed
None
Main program version
1 time
Display program version
2 time
None
3 time
Inlet valve for bleach detergent turns
on. (Cold Water)
4 time
Inlet valve for softener dispenser turns
on. (Hot water)
5 time
Inlet valve for J-dispenser turns on.
(Cold Water)
6 time
Heater check (on heater model)
7 time
Wave force check
8 time
Drain pump and agitate (pulsator) check
9 time
Load sensing check
10 time
Agitate (tub) check
11 time
High speed spin
12 time
Check Point
On :67~33 (26.7kHz~23.3kHz)
Off
. Unlocks the door
. Turns off all LED
T1 and main program version
T2 and display program version
T3
A and water level frequency (1~10 Level)
The meaning of 67~33 number is
26.7kHz~23.3kHz really
B and water level frequency (1~10 Level)
C and water level frequency (1~10 Level)
T4 and the coef
alpha is executed(RPM220,ON Time:180s)
T5 and
T6 and water level frequency
T7 and load sensing compensation
T8 and the coef
Current RPM
None