each separate sleeping area. If a bed-
room area hallway is more than 9 m long,
install a smoke alarm at each end. Install
a smoke alarm at the top of a first – to-
second floor stairwell.
MULTIPLE FLOOR PLAN
SINGLE FLOOR PLAN
Smoke alarms for minimum protection
Smoke alarms for additional protection
Ionisation type smoke alarm with
alarm silencer or photoelectric type
Don't install smoke alarms in the fol-
lowing places
1. Near appliances or areas where nor-
mal combustion
222360_palovaroitin_ko_en-fi-sv-et-lv-lt-ru_110x110mm.indd 2
222360_palovaroitin_ko_en-fi-sv-et-lv-lt-ru_110x110mm.indd 2
regularly occurs (kitchens, near furnac-
es, water heaters). Use special smoke
alarm with unwanted alarm to control for
these areas.
2. In areas with high humidity, like bath-
rooms or areas near dishwashers or
washing machines. Install at least 3 m
away from these areas.
3. Near return air or heating and cool-
ing vents. Install at least 1 m away from
these areas. The air could blow smoke
away from the detector and interrupt-
ing its alarm.
4. In rooms where temperatures may fall
below 0°C or rise above 40°C, or in hu-
midity higher than 93%. These condi-
tions will reduce battery life or cause
fault alarm.
5. In extremely dusty, dirty, or insect – in-
fested areas, influence particles can in-
terfere with smoke alarm operation.
Where is the best installation place
· At first you need install an alarm in the
bedroom and route way. In the case of
several bedrooms, you shall install an
alarm in every bedroom.
· Install it in the stairway and in ev-
ery floor.
· Smoke, heat and burning things spread
horizontally after rising to the ceiling, so
install the alarm on middle of the ceiling
of ordinary structure house
· If alarm couldn't be installed in the mid-
dle of the ceiling for some reasons, the
distance which the alarm from the wall
corner should be beyond 50 cm.
50 cm
CEILING
min.
Best here
Not in this
area
Acceptable here
500 mm
Not in this area
Do not install
500 mm
Not in this
area
1000 mm
Anywhere
in this area
Do not install
· If the length of the room or the hall is
beyond 9 m, you need install several
alarms in the hall.
· Smoke alarms in rooms with ceiling
slopes higher than 1 m in 8 m horizontal-
ly shall be located on the high side of the
room. Install a smoke alarm on sloping,
peak or cathedral ceiling between 500
mm and 1500 mm from the highest point
of the ceiling.

Installation Steps

· Remove the fixing plug from the mount-
ing plate (if necessary, use a screw driv-
er for this);
· Take off the bracket from the alarm
body.
19.10.2020 10.09.04
19.10.2020 10.09.04
10 cm
min.
30,5 cm
max.
SIDE
WALL
1000 mm
Anywhere
in this
area