For Installer; 5 Installer Setup System Setup; Optional Pcb Connectivity; Zone & Sensor - Panasonic WH-SDC0509L3E5 Operating Instructions Manual

Air-to-water heatpump
Hide thumbs Also See for WH-SDC0509L3E5:
Table of Contents

Advertisement

Menus

For installer

Menu

5 Installer setup System setup

5.1

Optional PCB connectivity

To connect to the external PCB
required for servicing.
• If the external PCB is connected (optional), the system will have following additional functions:
Control over 2 zones (including the swimming pool and the function to heat water in it).
1
Solar function (the solar thermal panels connected to either the DHW (Domestic Hot Water) Tank or the Buffer Tank.
2
• DHW is not applicable for WH-ADC models.
External compressor switch.
3
External error signal.
4
SG ready control.
5
Demand control.
6
Heat-Cool SW
7
5.2
Zone & Sensor
To select the sensors and to
select either 1 zone or 2 zone
system.
5.3

Heater capacity

To reduce the heater power if
unnecessary.*
3 kW / 6 kW / 9 kW
* Options of kW vary depending
on the model.
5.4

Anti freezing

To activate or deactivate the
water freeze prevention when
the system is OFF
5.5

Tank connection

To connect tank to the system.
32
Default Setting
Setting Options / Display
No
Zone
• After selecting 1 or 2 zone system, proceed
to the selection of room or swimming pool.
• If the swimming pool is selected, the
temperature must be selected for
T temperature between 0°C ~ 10 °C.
Sensor
For room thermostat, there is a further
selection of external or internal.
• If select internal, there is a further selection
of RC-1 or RC-2 (only available when Zone
selection is 1 zone system).
Select RC-1 if main remote controller's
thermistor is to be used for room temperature
control and vice versa.
Yes
No