CLEARANCES
In selecting a location for installation, it is necessary to provide adequate accessibility clearances for servicing and proper operation.
Locating the Vent Free Stove
When facing the front of the appliance the following minimum clearances to combustible construction must be maintained.
Top of appliance (ceiling)
Rear Wall
Side Wall
Provide adequate clearances around air openings.
Adequate accessibility clearances for purposes of servicing and proper operation must be provided.
Installation on Rugs and Tile
This appliance must be installed on a flat, solid, continuous surface (e.g. wood, metal, concrete). This may be the floor, or it
may be raised up on a platform to enhance its visual impact. The appliance may be installed on carpeting, vinyl, wood flooring
or other combustible material.
36" (915mm) TO CEILING OR
36" (915mm) TO CEILING OR
6" (153mm)
6" (153mm)
TO SIDE WALL
TO SIDE WALL
OR
OR
COMBUSTIBLE
COMBUSTIBLE
MATERIAL
MATERIAL
42605-3-0621
Empire Comfort Systems
918 Freeburg Avenue
Belleville, Illinois 62220-2623
The Empire Steel Stoves
VFD20MS(30,70)(N,P)-1 and
VFD30MS(30,70)(N,P)-1
36 inches
2 inches
6 inches
HORIZONTAL PROJECTION
HORIZONTAL PROJECTION
ABOVE APPLIANCE
ABOVE APPLIANCE
NOTE: HEATER INSTALLED
AT 45° ANGLE IN CORNER
NOTE: HEATER INSTALLED AT 45° ANGLE IN CORNER
NOTE: HEATER INSTALLED AT 45° ANGLE IN CORNER
Web Site: www.empirecomfort.com
Models:
Heater Corners (45° angle) to Wall
Floor
4" (102mm) HEATER CORNERS TO SIDE WALL
4" (102mm) HEATER CORNERS TO SIDE WALL
4"
4"
(102mm)
(102mm)
4 inches
0 inches
2" (51mm) TO COMBUSTIBLE MATERIAL
2" (51mm) TO COMBUSTIBLE MATERIAL