Overview Thank you for purchasing a Zen Spa 2 in 1 Boiling and Chilled Tap. The Zen Spa is a hot and cold drinks station that provides boiling water and filtered cold (ambient) drinking water. If desired an undersink chiller can be purchased to provide filtered chilled drinking water.
Page 3
The boiling tank must be placed on a solid surface where it will not be knocked over causing damage to the water hoses or electrical connections. The boiling tank must not be used in an area subject to flammable vapours such as paint, solvent or petrol.
Box Contents For Zen Spa with chiller (UC1 models) chiller sent separately. Zen Spa tap Zen tank Expansion vessel Manifold Expanssion vessel fixing bracket and metal band Pressure relief valve Scale filter Cold drinking water filter Hose ‘manifold to exp vessel’...
Page 5
1 x 3-way 3/8” to 1/4” PF 1/4” x 1/4” PF 2 x 1/2” BSP to 15mm 2 x 1/2” female to 3/8” PF 2 x Black rubber washer 1 x Large and 3 x small white washer 1.5 m x 1/4” and 3/8” tubing 6 x Large locking collar and 5 x small...
Page 6
A pressure reducing valve is required if the mains pressure is above 0.42 MPa (4.2 bar). The Zen Spa is factory set at 100°C. The temperature can be switched down to 98°C should this be desired. Please see Section 6 for further instructions.
Page 8
Step 1 - Prepare and Site the Tap • Choose a suitable location to mount the tap, this may be an existing hole in your sink or countertop. • If a new hole is required check that the reach of the spout will be appropriate for your sink before drilling the tap hole in the sink or worktop.
Page 10
Step 2 - Prepare Manifold Connections • It is imperative that no fittings, other than those specified in the instructions, are installed within the ‘expansion zone’ . This is everything beyond the check valve, located within the manifold. See Diagram 3. •...
Page 11
Step 3 - Mount Manifold and Connect Expansion Vessel • Orientation of the manifold is optional, but the direction of flow must follow the arrow on the manifold. The red handle is a service valve (boiling water isolation lever) for future maintenance. •...
Page 12
• Ensure all tubing is pushed fully into PF connectors and that locking collars are used to prevent inadvertant removal. • Use a suitable length of 3/8” tubing (cut using sharp knife, ensuring a clean straight cut) to connect from mains supply to t-piece supplied. •...
Page 13
Step 6 - Connect Cold Drinking Water Filter • If you are installing a chiller proceed to section 2. • Select a suitable location for the drinking water filter housing ensuring easy access for future maintenance. • Do not locate the filter above an electrical socket or other electrical device. •...
Page 14
2. Install Optional Water Chiller with Cold Drinking Water Filter Ensure you read separate chiller instructions for all important safety points and instructions before installation. Before commencing installation, ensure the location is a flat level surface that will allow for adequate airflow around all sides of the appliance. •...
3. Commission and Check Water Connections • Before plugging the tank into the power socket, the system must be full of water and tested for leaks. Open all water valves to allow water to flow to the boiling water tank. •...
If the status light begins flashing red this indicates a fault has been detected. The unit should be isolated from the power supply and the water supply shut off before contacting Hyco for further advice. Status Ring Summary Water is heating...
Operating the Tap • The tap handle has a safety lock mechanism on the boiling side. To release the safety lock, pull the handle away from the tap body. To dispense boiling water, rotate towards the red marker. • To dispense cold filtered drinking water rotate tap towards the blue marker. Releasing the safety lock is not required to dispense cold drinking water.
Page 19
Open the boiling side of the tap until water runs cold. • The Zen Spa is factory set at 100°C. The temperature of dispensed boiling water can be changed on the tank PCB. Switch between ‘LO’ 98°C or ‘HI’ 100°C.
Page 20
3L Model PC Board Diagram 5 6L Model PC Board Diagram 6...
Regularly inspect the appliance for any signs of water leaks or damage. If a leak or damage is discovered, discontinue use, isolate the water supply and drain down immediately. Contact Hyco. • The relief valve must be regularly tested. To do this twist the red cap until water flows from the valve.
SPA3L Zen Spa 100°C Tap 3L Boiling and Ambient SPA6L Zen Spa 100°C Tap 6L Boiling and Ambient SPA3LUC1 Zen Spa 100°C Tap 3L Boiling and 20L/ h Chilled SPA6LUC1 Zen Spa 100°C Tap 6L Boiling and 20L/ h Chilled...
Dispensed water is too hot Water temperature is set to Turn temperature down to 98°C 100°C on PC board. See Section 5 or 6 13. Dimensions Height (mm) Width (mm) Depth (mm) Zen Spa Tap Tank 3L Tank 6L...
Page 24
If you experience a problem with this product you should first contact our service department on 01924 225 200 before taking any further action. Experience has shown that issues can often be resolved without the need to return or uninstall the product. Hyco Manufacturing Ltd Normandy Court Express Way...
Need help?
Do you have a question about the Zen Spa and is the answer not in the manual?