  • Page 1 Product Instruction Manual Zen Solo SOLO3L, SOLO6L Boiling Water Tap v20.2.1...
  • Page 2: Key Features

    Overview Thank you for purchasing a Zen Solo 100°C instant boiling water tap. It replaces the need for a traditional kettle in the home, or counter/ wall mounted boiling water unit in the office. The Zen Solo can be installed over a sink or with the stylish, tempered glass design Zen Font.
  • Page 3 An RCD circuit breaker is strongly recommended. This unit dispenses boiling water. The boiling tank must be placed on a solid surface where it will not be knocked over causing damage to the water hoses or electrical connections. The boiling tank must not be used in an area subject to flammable vapours such as paint, solvent or petrol.
  • Page 4: Box Contents

    Box Contents Zen Solo tap Zen tank Expansion vessel Manifold Expanssion vessel fixing bracket and metal band Pressure relief valve Scale filter 1.5 m x 3/8” tubing Hose ‘manifold to exp vessel’ Hose ‘manifold to tank’ Hose ‘tank to tap’...
  • Page 5 2 x 1/2” BSP to 15mm 2 x 1/2” female to 3/8” PF 4 x Large locking collar 2 x Black rubber washer 1 x Large and 3 x small white washer...
  • Page 6 1. Installation Important Information The tank must be sited vertically and on a flat level surface. The supplied scale filter must be fitted and changed at least every 6 months, otherwise the lifespan of the product could be seriously reduced and the warranty may be void.
  • Page 8 Step 1 - Prepare and Site the Tap • Choose a suitable location to mount the tap, this may be an existing hole in your sink or countertop. • If a new hole is required check that the reach of the spout will be appropriate for your sink before drilling the tap hole in the sink or worktop.
  • Page 9 Diagram 2...
  • Page 10 Step 2 - Prepare Manifold Connections • It is essential that no fittings, other than those specified in the instructions, are installed within the ‘expansion zone’ . This is everything beyond the check valve, located within the manifold. See Diagram 3. •...
  • Page 11 Step 3 - Mount Manifold and Connect Expansion Vessel • Orientation of the manifold is optional, but the direction of flow must follow the arrow on the manifold. The red handle is a service valve (boiling water isolation lever) for future maintenance. •...
  • Page 12 Step 5 - Connect Mains Cold and Scale Filter • The supplied scale filter is suitable for up to 300 ppm. You may need to upgrade to a higher capacity filter in more aggressive water areas. Note these are larger in size so ensure sufficient space is available.
  • Page 13 • Secure the bracket to the wall using the fixings supplied. Replace the scale filter cartridge. • Use a suitable length of 3/8” tubing (cut using sharp knife, ensuring a clean straight cut) to connect from mains supply to scale filter head inlet, ensuring water flow arrow is followed.
  • Page 14 3. Commission and Check Water Connections • Before plugging the tank into the power socket, the system must be full of water and tested for leaks. • Open all water valves to allow water to flow to the boiling water tank. •...
  • Page 15 4. Electrical Connection • Before plugging the tank into the power socket, the system must be full of water and tested for leaks. • Ensure that the installation area is dry. • The boiling water tank is supplied with a pre-wired (1m) BS plug. •...
  • Page 16: Operation

    If the status light begins flashing red this indicates a fault has been detected. The unit should be isolated from the power supply and the water supply shut off before contacting Hyco for further advice. Status Ring Summary Water is heating...
  • Page 17 Operating the Boiling Tap • The boiling tap handle has a safety lock mechanism. To release the safety lock, pull the handle away from the tap body. To dispense boiling water rotate forwards. Operating the Tank • Once the boiling tank is installed following the correct installation instructions there should be no further operation required.
  • Page 18 6. Change Temperature Setting and Thermal Cut-out Reset • The appliance must first be isolated from the mains power supply by unplugging but is not necessary to isolate the water supply. • Open the boiling side of the tap until water runs cold. •...
  • Page 19 3L Model PC Board Diagram 8 6L Model PC Board Diagram 9...
  • Page 20: Maintenance

    Regularly inspect the appliance for any signs of water leaks or damage. If a leak or damage is discovered, discontinue use, isolate the water supply and drain down immediately. Contact Hyco. • The relief valve must be regularly tested. To do this twist the red cap until water flows from the valve.
  • Page 21: Descaling The Tank

    When re-installing follow the original installation instructions. 10. Descaling the Tank The tank should be descaled at least annually and more frequently in aggressive water areas. A service cartridge can be used. These are available from Hyco, please contact our service department for further information.
  • Page 22: Specification

    Thermal cut out has tripped Reset using cut out button. See lights Section 6 Tank not heating and red light Software error Contact Hyco flashing Water dripping from the tap Tap fault Contact Hyco Low flow from the tap Scale filter needs changing Replace scale filter cartridge.
  • Page 23 13. Dimensions Height (mm) Width (mm) Depth (mm) Zen Solo Tap Tank 3L Tank 6L 14. Guarantee This product is covered by a standard parts or replacement warranty for a period of 2 years from the date of purchase. If there is a manufacturing defect within the warranty period we will send spare parts, repair and return the unit or, at our discretion, supply a replacement product.