ELECTRICAL CONNECTION

4.2 ELECTRICAL INSTALLATION SAFETY

DANGER! Risk of fatal injury due to electric shock!
Ä
Electrical work may only be performed by qualified
and skilled personnel (see page 3).
Ä
Ensure correct polarity.
DANGER! Risk of fatal injury due to electric shock!
Ä
Be sure to maintain the time intervals as specified
by the inverter manufacturer between switching off
the inverter and beginning any further work.
18
18
INSTALLATION AND OPERATION MANUAL SOLAR MODULES Q.PEAK DUO L-G8.3 / BFG AND L-G8.3 / BGT – Q CELLS
DANGER! Risk of fatal injury due to electric shock!
Ä
Never plug or unplug the cable when under load.
Modules must not carry any current.
Switch off the inverter.
1.
EN
OFF
Switch off the DC circuit breaker.
2.
Measure shutdown in DC String.
3.
(no DC current flow).
Disconnect plugs by the use of appropriate
4.
and qualified tools of the manufacturer.
When connecting the modules proceed in reverse
5.
order.
4
ELECTRICAL CONNECTION

4.3 CONNECTION OF MODULES

Ä
Use solar cables for the connection at the junction
box outlet.
Ä
Only interconnect connectors of the same type
and manufacturer.
Ä
Use minimum No. 12 AWG copper wires insulated
for a minimum of 90 °C for field connections.
SOLAR
DANGER! Risk of fatal injury due to electric shock!
Ä
Ensure that all electrical components are in a
proper, dry, and safe condition.
Ä
Ensure for a tight connection between the plugs.
Plugs click together audibly.
click
click
click
click
INSTALLATION AND OPERATION MANUAL SOLAR MODULES Q.PEAK DUO L-G8.3 / BFG AND L-G8.3 / BGT– Q CELLS
NOTE! Module damage may occur!
Ä
Ensure that the cabling is not under mechanical stress
(Comply with bending radius of ≥ 2.36 in (60 mm)).
Ä
Ensure that the cables do not run between module
and mounting rail or structure (danger of pinch).
Ä
Position the wiring on the solar modules that
additional shading is avoided.
Ä
Do not connect modules with different orientations
or angles of inclination in the same string.
19