Download Print this page

Auto Power Off; Low Battery Indicator - Sealey TA320.V2 Manual

Digital automotive analyser/insulation tester - hybrid vehicles

Advertisement

Store capacitance
Enclosure
Shock (Drop Test)
Diode Test
Continuity Check
Peak
Temperature Sensor
Input Impedance
AC Response
AC True RMS:
ACV Bandwidth
Crest Factor
Display
Overrange indication

Auto Power Off

Polarity
Measurement Rate
Low Battery Indication
2000
Double molded, waterproof
6.5 feet (2 meters)
Test current of 0.9mA maximum, open
circuit voltage 2.8V DC typical
Audible signal will sound if the resistance is
less than 35Ω (approx.), test current
<0.35mA
Captures peaks >1ms
Requires type K thermocouple
>10MΩ VDC & >9MΩ VAC
True rms
The term stands for "Root-Mean-Square,"
which represents the method of calculation
of the voltage or current value. Average
responding multimeters are calibrated to
read correctly only on sine waves and they
will read inaccurately on non-sine wave or
distorted signals. True rms meters read
accurately on either type of signal.
50Hz to 1000Hz
≤3 at full scale up to 500V, decreasing
linearly to ≤1.5 at 1000V
40,000 count backlit liquid crystal with
bargraph
"OL" is displayed
15 minutes (approximately) with disable
feature
Automatic (no indication for positive); Minus
(-) sign for negative
2 times per second, nominal
"
" is displayed if battery voltage drops
below operating voltage

Advertisement

loading
Need help?

Need help?

Do you have a question about the TA320.V2 and is the answer not in the manual?

Questions and answers