Sealey TA320.V2 Manual page 22

Digital automotive analyser/insulation tester - hybrid vehicles

Advertisement

5.
Set the sample rate (from 1 to 255 S) for automatic recording.
In this mode, pressing the STORE button will start data
recording at the programmed sample rate.
6.
The auxiliary display on the left indicates the current storage
location (0000 to 9999). New measurements will begin storing
into the next available location.
7.
Press and hold the STORE button for 2 seconds to enter the
RECALL mode or press EXIT to return to the normal operating
mode.
DATA STORAGE RECALL
1.
Press and hold the STORE button for two seconds (if not
already done as instructed in step 7 in the above procedure) to
enter the RECALL function.
2.
The auxiliary display on the left will show XXXX (current
storage location). The auxiliary display on the right will show
XXXX (number of storage locations used).
3.
Use the + and - buttons to navigate the storage locations. The
value for the selected location is indicated in the main display.
4.
Press the EXIT button to end the recall session.
CLEAR ALL DATA
1.
From the OFF position, press and hold the RANGE button
while turning the function switch to any on position
2.
Release the RANGE button. The memory has been cleared