6015 HO Linear - Flush Facing Header Configuration & Facing
For installations where only non-combustible facing will cover the front of the appliance, the metal header can be moved
back ½" to accommodate drywall installed flush with the front of the fireplace The drywall can contact the top ½" of the
fireplace top.
Use a ¼" nut driver
to remove the (8)
screws that secure
the header
assembly to the top
of the fireplace
Slide the header
assembly back ½".
Align the header
assembly with the
second set of holes
in the fireplace.
Reattach the
assembly to the
fireplace (use the
screws removed in
the first step).
WARNING: For flush installations, combustible
facing can touch the first ½" if the
fireplace box. ONLY NON-
COMBUSTIBLE FACING can cover
the front of the appliance.
Page 13 of 28
Fireplace CoolSmart TV Kit
(54PB - sku# 98900775)(72PB, 6015 HO, 4237 EG & Firenze - sku# 98900776)
1/4" Nutdriver
17602016- 9/22/23
© Travis Industries, Inc.