6.

Connection

6.1.

Connecting the signal and power cables

*
*
* Optional accessories
** Power plug types vary by country/region.
Cautions
Connection is allowed up to 8 cabinets when the 110 VAC power supply is used.
Connection is allowed up to 16 cabinets when the 220 VAC power supply is used.
Max. daisy chain cable current rating: 10 Amp (please take this into account when you combine different cabinets)
Turn off the power of all devices first before connecting cables.
1. Connect the power cable from the "Power Out" port of the first cabinet to the "Power In" port of the second cabinet.
2. Connect the signal cable from the Data port of the first cabinet to Data port of the second cabinet for video signal
transmission. Connect the power cable from the "Power In" port of the first cabinet to the power outlet.
3. Connect one end of the data cable of the first cabinet to the LED display controller.
4. Repeating steps 2-3 enables the daisy chain connection.
Caution
Plug the power plug into the electric outlet only when the cables are properly wired.
Notes:
In some larger installations, you may need to do the wiring for RJ45 and power cables via the backside where opening is
unavailable. In such situation this can be solved by using 1 cabinet with 45 degree corner cut (75xx series) to have an opening
towards the backside for cables/wiring.
* *
*