A2. Hazardous Locations Certifications
Flame-proof and Dust:
II 2 G Ex db IIC
T6..T5 Gb
II 2 D Ex tb IIIC T 95
Intrinsically Safe:
II 1 G Ex ia IIC T4 Ga
II 3 G Ex ic IIC T4 Gc
C
ATEX
Non-Incendive
II 3 G Ex ec IIC T4 Gc
Enclosure: IP66/ IP67
STANDARDS: EN 60079-0: 2012+A11: 2013;
EN 60079-1: 2014; EN 60079-11: 2012; EN 60079-31: 2014;
EN 60079-7: 2015;
Flame-proof:
Ex db IIC T6..T5 Gb
o
Ex tb IIIC T 95
C Db
Intrinsically Safe:
Ex ia IIC T4 Ga
Ex ic IIC T4 Gc
D
IECEx
Non-Incendive
Ex ec IIC T4 Gc
Enclosure: IP66/ IP67
STANDARDS: IEC 60079-0: 2011; IEC 60079-1: 2014;
IEC 60079-11: 2011; IEC 60079-7: 2015; IEC 60079-31: 2014
Flame-proof:
Ex db IIC T6..T5 Gb
o
Ex tb IIIC T 95
C Db
Intrinsically Safe:
Ex ia IIC T4 Ga
Ex ic IIC T4 Gc
E
SAEx
Non-Incendive
Ex ec IIC T4 Gc
Enclosure: IP66/ IP67
STANDARDS: IEC 60079-0: 2011; IEC 60079-1: 2014;
IEC 60079-11: 2011; IEC 60079-7: 2006; IEC 60079-31: 2013
Explosion proof:
Class I, Division 1, Groups A,
B, C, D;T6..T4
Dust Ignition Proof:
Class II, III, Division 1, Groups
E, F, G; T4
Class I Zone 1 Ex db IIC T4 Gb
Ex db IIC T4 Gb
Zone 21 Ex tb IIIC T 95
o
Ex tb IIIC T 95
C Db
Intrinsically Safe:
CSA 14.2689056
Class I, II, III, Division 1,
Groups A, B, C, D, E, F, G; T4
Ex ia IIC T4 Ga
Non-Incendive
K
cCSAus
Class I, Division 2, Groups A,
B, C, D; T4
Class I Zone 2 Ex nA IIC T4 Gc
Ex nA IIC T4 Gc
Enclosure: 4X/ IP66/ IP67
Standards: CSA C22.2 No. 0: 2015; CSA C22.2 No. 30: 2016;
CSA C22.2 No. 94-M91; CSA C22.2 No. 25: 2017; CSA C22.2 No.
61010-1: 2017; CSA-C22.2No.157: 2016; C22.2 No. 213: 2017;
C22.2 No. CSA 60079-0:2015; C22.2 No. 60079-1: 2016; C22.2
No. 60079-11: 2014; C22.2 No. 60079-15: 2016; C22.2 No. 60079-
31: 2015;
ANSI/ ISA12.12.01-2017; ANSI/ ISA 61010-1: 2016; ANSI/ UL
60079-0: 2013; ANSI/ UL 60079-1: 2015; ANSI/ UL 60079-11:
2014; ANSI/ UL 60079-15: 2013; ANSI/ UL 60079-31: 2015 ;
FM 3600: 2011; FM 3615: 2006; FM Class 3616: 2011; ANSI/ UL
913: 2015; UL 916: 2015; ANSI/ UL 12.27.01: 2017; ANSI/UL 50E:
2015
Notes
1.
Operating Parameters:
Input: 4-20 mA; 42 VDC max, 30 mA
2. Intrinsically Safe Entity Parameters
For details see Control Drawing, 50089981.
34-ST-25-63
o
o
T6: -20
C to 65
C T95
Note 1
o
o
T5: -20
C to 85
C
o
C Db
o
o
Note 2
-20
C to 70
o
o
Note 1
-20
C to 85
ALL
ALL
o
o
T6: -20
C to 65
C T95
Note 1
o
o
T5: -20
C to 85
C
o
o
Note 2
-20
C to 70
o
o
Note 1
--20
C to 85
ALL
ALL
o
o
T6: -20
C to 65
C T95
o
o
Note 1
T5: -20
C to 85
C
o
o
Note 2
-20
C to 70
o
o
Note 1
--20
C to 85
ALL
ALL
T6: -50ºC to +65ºC
Note 1
T4, T5: -50 ºC to 85ºC
o
C Db
o
Note 2
-50
C to 70
o
Note 1
-50
C to 85
ALL
ALL
RMA801 Quick Start Guide
Flame-proof:
Ex db IIC T6..T5 Gb
o
C,
Ex tb IIIC T 95
Intrinsically Safe:
Ex ia IIC T4 Ga
Ex ic IIC T4 Gc
Non-Incendive
F
INMETRO
C
Ex ec IIC T4 Gc
Enclosure: IP66/ IP67
STANDARDS: ABNT NBR IEC 60079-0: 2013; ABNT NBR IEC
C
60079-1: 2016; ABNT NBR IEC 60079-11: 2013; ABNT NBR
IEC 60079-7: 2018; ABNT NBR IEC 60079-31: 2014
Flame-proof:
Ex d IIC T6/T5 Gb
Ex tD A21 IP66/67 T95
Intrinsically Safe:
Ex ia IIC T4 Ga
Ex ic IIC T4 Gc
o
C,
G
NEPSI
Non-Incendive
Ex nA IIC T4 Gc
Enclosure: IP66/ IP67
C
STANDARDS: GB 3836.1-2010; GB 3836.2-2010; GB 3836.4-
2014; GB 3836.19-2010; GB 3836.20-2010; GB 12476.1-2013;
C
GB 12476.5-2013
Flame-proof:
Ex db IIC T6..T5 Gb
Intrinsically Safe:
Ex ia IIC T4 Ga
o
C,
CCoE/
P
PESO
Enclosure: IP66/ IP67
STANDARDS: IEC 60079-0: 2011; IEC 60079-1: 2014;
C
IEC 60079-11: 2011; IEC 60079-7: 2006; IEC 60079-31: 2013
C
A4. Marking ATEX Directive
a.
General
The following information is provided as part of the labeling of the Remote
Indicator:
Name and Address of the manufacturer
The serial number of the Remote Indicator is located on the Meter Body
data-plate. The first two digits of the serial number identify the year (02)
and the second two digits identify the week of the year (23); for
example, 0223xxxxxxxx indicates that the product was manufactured in
2002, in the 23rd week.
b.
Apparatus Marked with Multiple Types of Protection
The user must determine the type of protection required for installation the
o
C
equipment. The user shall then check the box [ ] adjacent to the type of
protection used on the equipment certification nameplate. Once a type of
protection has been checked on the nameplate, the equipment shall not then
be reinstalled using any of the other certification types.
c.
WARNINGS and Cautions
o
C
Non-Incendive / Non-Sparking (Division 2 and Zone 2 Environments):
WARNING – EXPLOSION HAZARD – SUBSTITUTION OF
COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS I, DIVISION 2
Intrinsically Safe (Divisions 1, Zone 1 and Zone 2 Environments):
WARNING – EXPLOSION HAZARD – SUBSTITUTION OF
COMPONENTS MAY IMPAIR INTRINSIC SAFETY.
WARNING – DO NOT OPEN WHEN AN EXPLOSIVE GAS
ATMOSPHERE IS PRESENT.
Explosion-Proof (Division 1 and Zone 1 Environments):
WARNING – DO NOT OPEN WHEN AN EXPLOSIVE GAS
ATMOSPHERE IS PRESENT.
WARNING – DO NOT OPEN WHEN ENERGIZED
"OPEN CIRCUIT BEFORE REMOVING COVER"
Flameproof (Division 1 and Zone 1 Environments):
WARNING – DO NOT OPEN WHEN ENERGIZED
General Requirements / Increased Safety (Zone 1):
WARNING – DO NOT OPEN WHEN ENERGIZED
WARNING – OPEN CIRCUIT BEFORE REMOVING COVER
All Protective Measures:
WARNING: FOR CONNECTION IN AMBIENTS ABOVE 60
WIRE RATED 105
o
T6: -20
C to 65
o
Note 1
T5: -20
C to 85
o
C Db
o
Note 2
-20
C to 70
o
Note 1
--20
C to 85
ALL
ALL
o
T6: -20
C to 65
o
Note 1
T5: -20
C to 85
o
C
o
Note 2
-20
C to 70
o
Note 1
--20
C to 85
ALL
ALL
o
T6: -20
C to 65
Note 1
o
T5: -20
C to 85
o
Note 2
-20
C to 70
ALL
ALL
o
C
o
o
C T95
C,
o
C
o
C
o
C
o
o
C 95
C,
o
C
o
C
o
C
o
C
o
C
o
C
o
C USE
4

Advertisement

loading