OPERATING CONDITIONS
The following conditions should exist for maximum performance of the compressor. The truck
should be as close to level as possible when operating. The compressor will operate on a 15
degree sideward and lengthwise tilt without any adverse problems. Operation in ambient tempera-
tures above 100°F (38°C) may experience high temperature shutdown.
IF THE COMPRESSOR IS BEING USED TO POWER SANDBLASTING EQUIP-
MENT, OR AN AIR STORAGE TANK, USE A CHECK VALVE DIRECTLY AFTER
THE MINIMUM PRESSURE VALVE TO PREVENT BACKFLOW INTO THE SUMP.
THIS CHECK VALVE SHOULD HAVE A MAXIMUM PRESSURE DROP RATING
OF 2 PSIG (13.78kPa) OPERATING AND A CAPACITY RATING EQUAL TO THE
COMPRESSOR.
A COMPRESSOR SERVICE VALVE SHOULD BE LOCATED TO THE HOSE REEL
INLET OR THE CUSTOMERS AIR CONNECTION PORT WHEN A HOSE REEL IS
NOT USED. TYPICAL PLUMBING FROM THE MACHINES AIR OUTLET PORT
IN THE FOLLOWING ORDER:
1. MOISTURE TRAP/GAUGE/OILER COMBINATION (WHEN USED).
2. AIR TANK (WHEN USED).
3. HOSE REEL (WHEN USED).
COMPRESSOR OPERATION