This water heater design has been certified to
CSA 4.3:19 standard as a direct vent automatic instantaneous water
heater / furnace, designed to be installed in recreational vehicles or
manufactured (mobile homes).
This water heater is not for use in
space heating applications.
SERVICE CALLS & QUESTIONS
Locations and phone numbers of qualified Service Centers can
be found at our website www.precisiontemp.com or
800-934-9690 Ext. 110 to obtain service information.
call
WARNING: If the information in these
instructions is not followed exactly, a
fire or explosion may result causing property
damage, personal injury or loss of life.
—Do not store or use gasoline or other
flammable vapors and liquids in the vicinity
of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
• Evacuate all persons from the
vehicle.
• Shut off the gas supply at the gas
container or source.
• Do not touch any electrical switch,
or use any phone or radio in the
vehicle.
• Do not start the vehicle's engine or
electric generator.
• Contact the nearest gas supplier or
qualified service technician for
repairs.
• If you cannot reach a gas supplier
or qualified service technician,
contact the nearest fire department
• Do not turn on the gas supply until
the gas leak(s) has been repaired.
Installation and service must be
performed by a qualified installer,
service agency, OEM or the gas
supplier.
REV 3/23
local codes, the Standard for Recreational Vehicles, ANSI A119.2/NFPA 50
Patent Pending.
IAPMO-T®
c
Certified to ANSI Z21.10.3 / CSA4.3:19
BTU / HR Input:
Fuel:
Inlet Pressure:
Manifold Pressure:
CSA ANSI Z21.10.3 *
Power Input:
Operating Pressure:
Max. Water Temp:
Orifice Size:
Tank Volume:
Recovery Rating:
Elec. Element(s):
Minimum clearances from combustible
and noncombustible construction is 1"
(25mm) on the sides, back and top.
WHAT TO DO IF YOU SMELL GAS:
WHAT TO DO
WHAT TO DO
WHAT TO DO
1. Evacuate all persons from the vehicle.
2. Shut off the gas supply at the gas container or source.
3. Do not touch any electrical switch, or use any phone or
radio in the vehicle.
4. Do not start the vehicle's engine or electric generator.
5. Contact the nearest gas supplier or qualified service technician for rep
6. If you cannot reach a gas supplier or qualified technician, contact the
nearest fire department.
7. Do not turn on the gas until the gas leak(s) has been repaired.
Label Size: 6.0" Wide x 8.5" Tall
Radius Corners:
Label Corners: 0.25"
Inside Note Boxes: 0.12"
"Warning"/"For Your Safety" Box: 2.0" Wide x 3.5" Tall with a 0.05" Thick Border
"What to do if......" Box: 5.5" Wide x 1.9" Tall with a 0.05" Thick Border
1.
55,000 – 12,000
Propane
10.5" WCI Min. to
14" WCI max.
1.30" – 9.20" WCI
12 VDC
Installation, Operation and Maintenance
125 PSI Max.
Effective 3/23
(8.6 Bar)
Max.
145°F
#71 x 12
2.5 US Gal
CRITICAL INSTALLATION WARNINGS
54
120
60
• All combustion air must be supplied from outside the RV, and all
vac,
products of combustion must be vented to outside the RV.
• DO NOT vent water heater with venting system serving another
appliance.
• DO NOT vent water heater to an outside enclosed porch area.
• Protect building materials from flue gasses.
• DO NOT modify water heater in any way.
IF YOU SMELL GAS:
IF YOU SMELL GAS:
IF YOU SMELL GAS:
• DO NOT alter water heater for a positive grounding system.
• DO NOT HI-POT water heater unless electronic ignition system
(circuit board) has been disconnected.
• DO NOT use battery charger to supply power to water heater
even when testing.
The installation, must comply to local codes or in the
absence of local codes must conform to one of the
following:
* The National Fuel Gas Code, ANSI Z223.1/NFPA 54
and/or CSA B149.1, Natural Gas and
Propane Installation Code
* The Manufactured Home Construction and Safety
Label Specifications:
Standard, Title 24 CFR, Part 3280 and/or
CSA Z240 MH Series, Manufactured Homes; or
* Recreational Vehicle, NFPA 1192, and/or CAN/CSA-
Z240 RV Series.
If an external electrical source is utilized, the appliance,
when installed, must be electrically grounded in
accordance with local codes or in the absence of local
codes, with the National Electrical Code, ANSI/ NFPA 70,
and/or CSA C22.1, Canadian Electrical Code, Part 1.
CLEARANCE Requirements
Sides, top and bottom - 0"
Back - Enough to make connections, but no less
than 2.5"
Front - Enough to remove access cover for service,
but no less that 10". Unit should be installed where it
can draw combustion air into the bottom directly from
the coach exterior and flued through the 2" flue pipe
to the exterior. The combustion air source and flue
pipe must be totally isolated from the inside of the
coach.
WARNING:
LPG GAS ON DEMAND
If the information in
WATER HEATER
instructions is not
followed exactly, a f
explosion may resu
Model
causing property
550NSP-EC
damage, personal in
or death.
FOR YOUR SAFE
Do not store or use
gasoline or other
10 Amp
flammable vapors a
liquids in the vicinit
this or any other
appliance.
(63°C)
Installation and
Service:
(9.5L)
Must be preformed b
qualified installer, s
12.5
Hz,
amps
agency or gas supp
"Clear Window (0.4" x
Serial No:

Advertisement

loading
Need help?

Need help?

Do you have a question about the cIAPMO-T 550NSP-EC and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for PrecisionTemp cIAPMO-T 550NSP-EC

  • Page 1 Orifice Size: Locations and phone numbers of qualified Service Centers can Service: 2.5 US Gal (9.5L) be found at our website www.precisiontemp.com or Tank Volume: CRITICAL INSTALLATION WARNINGS Must be preformed b 800-934-9690 Ext. 110 to obtain service information. call...
  • Page 2: General Installation

    “basement” or luggage compartment. 
 Consult your Field Auditor, Account Manager, or the PrecisionTemp Service Department if you have additional All connections must be made using TWO questions. (2) wrenches to avoid twisting and damaging Mounting Unit lines.
  • Page 3: Wiring Instructions

    The appliance must be disconnected from the gas WIRING INSTRUCTIONS supply piping system during any pressure testing of the 
 The heater must be connected to fully rectified system at test pressures in excess of ½ psi. The 12 VDC power supply rated at 5 amps. Take care appliance must be isolated from the gas piping system during any pressure testing at test pressures equal to to assure that the...
  • Page 4 General Information and Maintenance • Periodically inspect the venting systems to assure that it is clean with no obstruction. • Keep appliance area clear and free from combustible materials, gasoline and other flammable vapors and liquids. • LPG and Water systems must be turned on •...
  • Page 5 NSP-550-EC Component Layout 
 Hall Sensor Flow Meter Gas Modulation Valve Power Vent NOT PICTURED Fluing Vacuum Switch 12 VDC Relay Combination Gas Valve Control Board Igniter / Proofing Probe Direct Spark Ignition Board Manifold and Burner Finned Tube Heat Exchanger NOTE Flue Hood COMPONENT LAYOUT OF...
  • Page 6: Winter Driving Instructions

    LED light on the green control board. A red flashing LED indicates a self diagnostic trouble code; refer to the Service Manual or call PrecisionTemp for assistance. When adjusting water temperature it is best to start with hot only and slowly add cold into the mix until the desired temperature is reached.
  • Page 7 550-EC Water Heater Winter Driving Draining Instructions 1. Turn off water supply. 2. Open all hot water faucets. 3. Remove the 550-EC door and open the Pressure Relief Valve by moving the lever to the open position. 4. The water lines and the 550-EC will now drain. 5.
  • Page 8 90°while power is turned off. Never perform this operation while the burner is operating or scalding could occur. Never plug the pressure relief valve. If the valve is actuating too frequently contact PrecisionTemp or replace valve 7. Unplug all connectors and reconnect with power turned off. Inspect and clean corrosion from the ignition cable/spark probe connection and the ground wire connection.
  • Page 9 The 550-EC freeze protection system will not work if the electrical power source or propane is disconnected. Your heater is equipped with the cold weather protection package (call PrecisionTemp for details). WARNING: Under no circumstances should you travel during freezing conditions without first draining water from the 550-EC.
  • Page 10: Troubleshooting

    A periodic visual check of the burner flames should be done by observing the flame through the opening from the probe to the burner. Contact PrecisionTemp or your nearest authorized service representative. in the heat exchanger. There should be blue flame 5.