PrecisionTemp cIAPMO-T RV-550 Manual

Lpg gas on demand water heater, certified to ansi z21.10.3 / csa4.3

Advertisement

Quick Links

11 Sunnybrook Drive
Cincinnati, OH. 45237
Phone: 513-641-4446 * 800-934-9690
Fax:
513-641-0733
www.precisiontemp.com
This water heater design has been certified by the Canadian
Standards Association for installation in recreation vehicles. This
water heater is not for use in space heating applications.
SERVICE CALLS & QUESTIONS
Locations and phone numbers of qualified Service Centers can
be found at our website www.precisiontemp.com or
800-934-9690 Ext. 109 to obtain service information.
call
WARNING: If the information in these
instructions is not followed exactly, a
fire or explosion may result causing property
damage, personal injury or loss of life.
—Do not store or use gasoline or other
flammable vapors and liquids in the vicinity
of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
• Evacuate all persons from the
vehicle.
• Shut off the gas supply at the gas
container or source.
• Do not touch any electrical switch,
or use any phone or radio in the
vehicle.
• Do not start the vehicle's engine or
electric generator.
• Contact the nearest gas supplier or
qualified service technician for
repairs.
• If you cannot reach a gas supplier
or qualified service technician,
contact the nearest fire department
• Do not turn on the gas supply until
the gas leak(s) has been repaired.
Installation and service must be performed
by a qualified installer, service agency, OEM
or the gas supplier.
local codes, the Standard for Recreational Vehicles, ANSI A119.2/NFPA 501C
Patent Pending.
IAPMO-T®
c
Certified to ANSI Z21.10.3 / CSA4.3
BTU / HR Input:
Fuel:
Inlet Pressure:
Manifold Pressure:
Power Input:
Operating Pressure:
Max. Water Temp:
Orifice Size:
Tank Volume:
Recovery Rating:
Elec. Element(s):
Minimum clearances from combustible
and noncombustible construction is 1"
(25mm) on the sides, back and top.
WHAT TO DO IF YOU SMELL GAS:
WHAT TO DO
WHAT TO DO
WHAT TO DO
1. Evacuate all persons from the vehicle.
2. Shut off the gas supply at the gas container or source.
3. Do not touch any electrical switch, or use any phone or
radio in the vehicle.
4. Do not start the vehicle's engine or electric generator.
5. Contact the nearest gas supplier or qualified service technician for repa
6. If you cannot reach a gas supplier or qualified technician, contact the
nearest fire department.
7. Do not turn on the gas until the gas leak(s) has been repaired.
Label Size: 6.0" Wide x 8.5" Tall
Radius Corners:
Label Corners: 0.25"
Inside Note Boxes: 0.12"
"Warning"/"For Your Safety" Box: 2.0" Wide x 3.5" Tall with a 0.05" Thick Border
"What to do if......" Box: 5.5" Wide x 1.9" Tall with a 0.05" Thick Border
1
LPG GAS ON DEMAND
WATER HEATER
Model
55,000 – 12,000
RV-550
Propane
10.5" WCI Min. to
14" WCI max.
1.30" – 9.20" WCI
Installation, Operation and Maintenance
12 VDC
10 Amp
Effective 3/13
125 PSI Max.
(8.6 Bar)
Max.
145° F
(63° C)
#71 x 12
!
CRITICAL INSTALLATION WARNINGS
2.5 US Gal
(9.5L)
54
• Install in recreation vehicles only. RV's are recreation vehicles
120
60
12.5
vac,
Hz,
designed as temporary living quarters for recreation, camping, or
travel use having their own power or towed by another vehicle.
• All combustion air must be supplied from outside the RV, and all
products of combustion must be vented to outside the RV.
Serial No:
• DO NOT vent water heater with venting system serving another
appliance.
• DO NOT vent water heater to an outside enclosed porch area.
IF YOU SMELL GAS:
IF YOU SMELL GAS:
IF YOU SMELL GAS:
• Protect building materials from flue gas exhaust.
• Install water heater on an exterior wall, with access door
opening to outdoors.
• DO NOT modify water heater in any way.
• DO NOT alter water heater for a positive grounding system.
• DO NOT HI-POT water heater unless electronic ignition system
(circuit board) has been disconnected.
• DO NOT use battery charger to supply power to water heater
even when testing.
Do not install close to opening door or under room slide-
out where the vent or inlet louvers can be obstructed.
Label Specifications:
USA and Canada – Follow all applicable state
and local codes. In the absence of local codes or
regulations, refer to the current standards of:
— Local codes or, in the absence of local
codes, the National Fuel Gas Code, ANSI
Z223.1/NFPA 54 and/or CSA B149.1, Natural
Gas and Propane Installation Code.
— Local codes or, in the absence of local
codes, the Standard on Recreational
Vehicles, NFPA1192 and/or CAN/CSA-Z240
RV.
CUTOUT Requirements
OEM and Aftermarket – Unit can be installed in
PrecisionTemp, Suburban and Girard openings. Unit can also
be installed through the wall from exterior, or prior to erecting
wall into place at OEM manufacturing facility.
Rough opening:
14.25" min. - 16.5" max High
13.5" min - 17.25" max Wide
17" min Deep
WARNING:
If the information in th
instructions is not
followed exactly, a fire
explosion may result
causing property
damage, personal inju
or death.
FOR YOUR SAFET
Do not store or use
gasoline or other
flammable vapors and
liquids in the vicinity o
this or any other
appliance.
Installation and
Service:
Must be preformed by
qualified installer, serv
amps
agency or gas supplie
"Clear Window (0.4" x 2

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the cIAPMO-T RV-550 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for PrecisionTemp cIAPMO-T RV-550

  • Page 1 CUTOUT Requirements or the gas supplier. OEM and Aftermarket – Unit can be installed in PrecisionTemp, Suburban and Girard openings. Unit can also be installed through the wall from exterior, or prior to erecting wall into place at OEM manufacturing facility.
  • Page 2: General Installation

    Consult your Field Auditor, Account Manager, or Erect the side walls and cut the opening or the PrecisionTemp Service Department if you have additional orient the pre-fabricated opening. Frame with 2”...
  • Page 3: Wiring Diagram

    PRESSURE RELIEF VALVE PRESSURE RELIEF VALVE WIRING INSTRUCTIONS The appliance, when installed, must be WIRING INSTRUCTIONS electrically grounded in accordance with local The appliance, when installed, must be electrically codes or, in the absence of local codes, with the grounded in accordance with local codes or, in the National Electrical Code, ANSI/NFPA 70 and/or absence of local codes, with the National Electrical the CSA C22.1, Canadian Electrical Code.
  • Page 4 Pressurize the water system by turning on pump or city water pressure. Purge all air from the system by turning on the faucets until a steady stream of water flows. Turn on the 12V DC power supply. Turn on the LP supply at the tank and the manual gas valve (if installed).The water heater will remain dormant until a water tap is opened and the heater senses water flow of at least 0.5 GPM.
  • Page 5 Orifice #72 (45,000 Btu) Orifice #71 (50,000 Btu) Orifice .027” (55,000 Btu) Pressure Elbow Standard Door Kit Color Req Large Door Kit Color Req Optional Winter Kit Grommet Burner Assembly 1315 Burner Mounting Bracket 2454 Igniter 1411 Pressure Relief Valve (PRV) 1375 Moderating Valve Assembly 1385...
  • Page 6: Troubleshooting

    If problems still persist, air. contact PrecisionTemp or an authorized service 2. Be sure that water flow is at least 0.5 gallon/ center. Only a qualified technician should do any minute.
  • Page 7: Limited Warranty

    (under 3/8 inch outside diameter). The 1. For a period of two years from the date of purchase, PrecisionTemp will gas line may be excessively long (over 20-30 feet) or replace the complete water heater if the heat exchanger leaks due to corrosion.
  • Page 8: Mounting Unit

    Mounting Instructions for the OD55-B unit (RV-550 NSP) CRITICAL INSTALLATION WARNINGS • Install in recreation vehicles only. RV’s are recreation vehicles designed as temporary living quarters for recreation, camping, or travel use having their own power or towed by another vehicle. •...

Table of Contents