Jøtul F 400 ECO UKCA
2
3

Advertisement

Table of Contents
loading

Summary of Contents for Jøtul F 400 ECO

  • Page 1: Dimensions, Distances See Fi G

    Jøtul F 400 ECO UKCA UKCA information UK - Installation and operating instructions The manuals which are enclosed with the product must be kept throughout the product’s entire service life. Les manuels fournis avec le produit doivent être conservés pendant toute la durée de vie du produit.
  • Page 2 Attention! Use this approval label when the stoves has been installed (only for UK). Cut off the bottom part and replace the label already attached with this one. It is important that the lot + pin number is viewable. Note: An approved CO monitor should be installed in the same room as the appliance.
  • Page 3: Table Of Contents

    Ø 150 mm/177 cm cross- section troubleshooting Outside air connection Alu. fl ex - Ø 80 mm Approx. weight for Jøtul F 400 ECO ca 158 kg 9.0 Optional equipment Optional equipment Heat shield rear, External air kit, Self closing door 10.0 Recycling...
  • Page 4: Safety

    ENGLISH 3.0 Safety Jøtul F 400 ECO has a heat shield underneath which protects the fl oor from radiation. The product can therefore be placed directly on a wooden fl oor taht is covered by a metal plate NB! To guarantee optimal performance and safety, Jøtul or other suitable, non-infl...
  • Page 5 ENGLISH...
  • Page 6: Installation

    ENGLISH 4.0 Installation Fig. 4 Mount the ash lip • Before installing the fi replace, check it carefully for any signs of damage. • The product is heavy! Ask someone to help you when positioning and installing it. • Make sure that furniture and other household items are at a safe distance from the fi...
  • Page 7 The product is assembled for a top outlet as standard. The amount of combustion air for Jøtul’s products is approximately 20-40 m /h. The outside air connection may be fi tted directly to the Jøtul F 400 ECO through: Fig. 6 Assembling the fl ue pipe • the bottom •...
  • Page 8 ENGLISH 4.4 Location of approval label Fig. 7d indirecitly through an outside wall Fig. 9 Approval label Fig. 8a Mounting of external air supply connection 1. The approval label is located at the bottom of the stove. 4.5 Chimney and fl ue pipe •...
  • Page 9: Requirement For Uk - Smoke Control Areas

    Fig. 10 The Jøtul F 400 ECO is equipped with the Your local authority is responsible for implementing the Clean following operating options: Air Act 1993 including designation and supervision of smoke control areas and you can contact them for details of Clean Air Act requirements.
  • Page 10: Daily Use

    ENGLISH 5.0 Daily use Fig. 14 5.1 Odours when using the fi replace for the fi rst time When the fi replace is used for the fi rst time, it may emit an irritating gas which may smell slightly. This happens because the paint dries.The gas is not toxic but the room should be thoroughly ventilated.
  • Page 11 ENGLISH 5.6 Wood consumption 5.8 Removing the ashes Jøtul F 400 ECO has a nominal heat output of ca. 7 kW. Use • Only remove ashes when the fi replace is cold. of wood, with nominal heat emission: Approx. 1,84 kg/h. The •...
  • Page 12: Maintenance

    ENGLISH 5.10 Condensation 6.2 Cleaning and soot removal Condensation in a fi replace / fl ue pipe / chimney may occur. Soot deposits may build up on the internal surfaces of the This may be caused by moist fi rewood or diff erences in fi...
  • Page 13: Service

    ENGLISH 7.0 Service Fig. 18b Removing the baffl e plate Any unauthorised modifi cations to the product are prohibited! Only original spare parts may be used! Fig. 17 2. The baffl e plate loosens in the rear and can be lifted out 3.
  • Page 14 ENGLISH 7.3 Replacing the burn plates Fig. 21a Replacing the rear burn plate Fig. 20a Replacing the side burn plate NB: Remove the baffl e plate fi rst (see fi g.18a) 1. Loosen the rear burn plate by removing the screws shown in the fi...
  • Page 15 ENGLISH 7.5 Replacing the valve handle Fig. 21d Fig. 23a 5. Apply cement (A) on the new rear burn plate. Fig. 21e 1. Loosen the 2 screws located inside the front. Fig. 23b 6. Apply cement (A) on the new rear burn plate. 7.
  • Page 16: Operational Problems - Troubleshooting

    ENGLISH 9.0 Optional equipment Fig. 23d 9.1 Heat shield rear Cat. no: 50012949 Black paint (BP) Cat. no: 50012950 Aluzink See manual: 10026623 9.2 External air kit Ø 80 Cat. no: 51047509 See manual: 10047508 9.3 Self closing door mechanism 5.
  • Page 17: Guarantee Terms

    ENGLISH 11.0 Guarantee terms 1. Our guarantee covers: Jøtul AS guarantees that the external cast-iron parts are free from defects in materials or manufacturing at the time of purchase. You may extend the guarantee on the external cast- iron parts to 25 years from the date of delivery by registering the product on jotul.com, and print out the extended guarantee card within three months of purchase.
  • Page 18 Jøtul arbeider kontinuerlig for om mulig å forbedre sine produkter, og vi forbeholder oss retten til å endre spesifi kasjoner, farger og utstyr uten nærmere kunngjøring. Jøtul AS arbejder kontinuerlig med om mulig at forbedre sine produkter, og vi forbeholder os ret til at endre specifi...