  • Page 1 QUICK GUIDE v1.0 DRUMFILTER ECO20...
  • Page 2: Table Of Contents

    QUICKGUIDE Index BASIC REQUIREMENTS ....................3 1.1 Control unit ......................4 A. GRAVITY-SYSTEM ....................6 2.1 Placing the filter system ..................6 2.2 Set level control: ...................... 8 B. PUMP FED SYSTEM ....................9 3.1 Placing filter system ....................9 3.2 Set level control: ....................
  • Page 3: Basic Requirements

    QUICKGUIDE 1 Basic requirements Basic requirements every filter system must meet:  The filter system should be placed on a ground surface with sufficient carrying capacity, for instance: − a well-vibrated sand bed of 10 cm, possibly with concrete tiles −...
  • Page 4: Control Unit

    QUICKGUIDE 1.1 Control unit Power Switch Manual Cleaning Plug Plug Sensor Motor Drumfilter Plug Plug Cleaning Pump Circulation Pump...
  • Page 5 QUICKGUIDE 1. Fuse (motor drumfilter) (cleaning pump) 2. Fuse (pond pump) (power supply) 3. Timer 4. Relay 1 − Cleaning pump − motor drumfilter 5. Relay 2 − Pond pump 6. Power supply Adjust cleaning time...
  • Page 6: Gravity-System

    QUICKGUIDE GRAVITY 2 A. Gravity-system 2.1 Placing the filter system  Determine the maximum water level of the pond.  Align the base plate horizontally (the filter should be placed fully level).  The filter should be placed the height of the installation height (fig. 2.1) above water level. (installation height is the distance from maximum water level to top of filter).
  • Page 7 QUICKGUIDE GRAVITY Schematic setup of the drum filter Pic. 2.1 1. Water level with running pump after rinse (8 cm above upper float switch) 2. Start rinsing 3. Pond pump switches off 4. Installation height ECO20 is 16 cm...
  • Page 8: Set Level Control

    QUICKGUIDE GRAVITY 2.2 Set level control:  For the operation of the gravity system a constant water level in the pond is necessary. A tolerance of up to 20 mm below maximum water level is allowed.  Should the maximum water level in the pond exceed this, the water excess water will be disposed of via the waste water drain, until the maximum water level has been reached Pic.
  • Page 9: Pump Fed System

    QUICKGUIDE PUMP FED 3 B. Pump fed system 3.1 Placing filter system  Determine the maximum water level of the pond  Align the base plate horizontally (the filter should be completely level).  The installation height is 30 cm (installation height is the distance from maximum water level to the top of the filter) Schematic setup of the drum filter Pic.
  • Page 10: Set Level Control

    QUICKGUIDE PUMP FED 3.2 Set level control: Pic. 3.2Float switch 1. Water level with running pump after rinse 2. Start rinsing 3. Pond pump switches off...