Error Type
Error Mode
LED
Heater Error
Hr
36
(Heater
Relay)
9E1
Overflow error
OE
E
29
Temperature
Sensor Error
Unbalance
dC
10
Error
Silver Care Kit
7E
(Silver Care
PCB) Failure.
Mems or Har- 8E
Foaming
SUdS
Detected
Sd
Check whether the washing machine is level to the floor with respect to the original position of the washing machine prior
to service. Doing this now will reduce the need for a redo call and customer dissatisfaction.
✔ Vibrations can shorten the lifetime of the product.
Foot Pad for Walking Washer, There
is one in each package, so order 4
Details
LCD
This can be a short or a wire disconnected to the heater circuit. This
can also be problem with the tub contacting the heater or if the wa-
ter in the tub is frozen or there is no water. The error is triggered by
temperatures above 145C. If the heater has no error, this occurs
because of a PBA relay malfunction. Check the wiring harness to
the heater.
An Hr error occurs if the steam heater, is faulty, replace it.
EMC Filter issue or a noise spike from an external device
Water is supplied continually because the water level detection
does not work. - Verify the drain is working properly, the water level
detection does not work and water is supplied continually. Verify the
water valves shut off fully. Finally check the water level sensor.
The washing heater temperature sensor in the tub has an error.
Check the connections for the washing heater temperature sensor
connector.
Check the type of laundry. Check whether it may cause an unbal-
anced situation.- Educate the consumer in this case, to press
pause, reposition the load or remove a few items. Press start to
continue and complete the wash cycle.
This occurs when too much foaming is detected. It is also displayed
while foaming is removed. When the removal is finished, the normal
cycle proceeds. (This is one of the normal operations. It is an error
for preventing non-sensing faults.)
When installing a washer and dryer on the first, or second floor, do not
exceed this leg adjustment height for stability.
Check Silver Care PCB ,Main PCB & Wire-harness
Check MEMS PCB ,Main PCB & Wire-harness