Sharp 32U-S50B Service Manual page 9

Hide thumbs Also See for 32U-S50B:
Table of Contents

Advertisement

B. SPECIAL SETTING
SERVICE
ADJUSTMENT ITEM
NUMBER
EX1
FAO VOLUME
EX2
CC-POSITION
EX3
INT
EX4
A-ATT
EX5
TUNER data
EX6
Think chip-Slice LEVEL
EX7
RLY DELAY TIME
EX8
ADG ON TIME
C. OPTION SETTING
SERVICE
ADJUSTMENT ITEM
NUMBER
OP1
OPTION1
OP2
OPTION2
OP3
OPTION3
D. SOUND ADJUSTMENT
SERVICE
ADJUSTMENT ITEM
NUMBER
M01
INPUT LEVEL
M02
MTS VCO
M03
FILTER
M04
WIDEBAND
M05
SPECTRAL
Holding down both the VOL-up and CH-up buttons on the TV set at service mode for more than 2 seconds will
automatically write the above initial values into IC2101.
PART REPLACED
NECESSARY
IC2001
IC201
IC2101
CRT
IC3001
DATA
RANGE
0-50 (00h-32h)
0-127 (00h-7Fh)
0-255 (00h-FFh)
0-127 (00h-7Fh)
0-3 (00h-03h)
0-255 (00h-FFh)
0-255 (00h-FFh)
0-255 (00h-FFh)
DATA
RANGE
0-255 (00h-FFh)
0-255 (00h-FFh)
0-255 (00h-FFh)
DATA
RANGE
0-15 (00h-0Fh)
0-63 (00h-3Fh)
0-63 (00h-3Fh)
0-63 (00h-3Fh)
0-63 (00h-3Fh)
ADJUSTMENT
UNNECESSARY
X
X
X
X
X
NOTE
INITIAL VALUE
36 (24h)
27 (1Bh)
122 (7Ah)
Interrupt period adjustment.
90 (5Ah)
0 (00h)
54 (36h)
0 (00h)
For the power control
10 (0Ah)
For the power control
NOTE
INITIAL VALUE
247 (F7h)
253 (FDh)
15 (0Fh)
NOTE
INITIAL VALUE
7 (07h)
38 (26h)
36 (24h)
28 (1Ch)
23 (17h)
NOTES
Data is stored in IC2101.
The adjustment is needed to compensate for characteristics of parts
including IC201 and MTS level (M01).
Holding down both the VOL-up and CH-up buttons on the TV set in
the service mode for more than 2 seconds will automatically write the
above initial values into IC2101 Then perform a complete adjustment.
Adjust items related to picture tube only.
Adjust items related to MTS only (M01~M20).
9
32U-S50B
32U-S60B
FIXED VALUE
(HEX)
24
1C
7A
5A
00
12
00
0A
FIXED VALUE
(HEX)
B0
08
0C
FIXED VALUE
(HEX)

Advertisement