Download Print this page

GE Lumination LRX Series Installation Manual page 4

Led luminaire construction frame

Advertisement

Lumination
(LRX - Series)
®
Connect plugs:
3 pole to 3 pole
2 pole to 2 pole
Connect the two quick connectors and reassemble the
8
connector box.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation. CAN ICES-005 (A) / NMB-005 (A).
Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference
to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to
correct the interference at his own expense.
LED.com
© 2023 Current Lighting Solutions, LLC. All rights reserved. Information and specifications subject to change
without notice. All values are design or typical values when measured under laboratory conditions.
Reassemble
connector box
RISK OF PERSONAL INJURY - Operators shall ensure no appendages
are in the path of the torsion springs as they are a pinch hazard when
released. The springs will release when the arm is flexed downward. Be
cautious that no body part is in the path of the spring when released.
RISQUE DE BLESSURE CORPORELLE - Les techniciens veilleront à
ce qu'aucun appendice ne se trouve sur le chemin des ressorts de
torsion, car ils présentent un risque de pincement lorsqu'ils sont
libérés. Les ressorts seront libérés au moment de fléchir le bras vers le
bas. Faites attention à ce qu'aucune partie du corps ne se trouve sur le
chemin du ressort à sa libération.
Load springs into upright position by twisting the springs
9
upward and carefully insert the fixture to the hole of the
frame. Verify reflector trim is flush with ceiling.
NOTE: Please make sure the spring rides on the bracket
with the arrow mark.
CAUTION
IND327-Lumination-LRX-Series-Square-LED-Luminaire-Installation-Guide_R01
Installation Guide
Spring
Page 4 of 4
(Rev 05/19/23)

Advertisement